Date |
Text |
2004-02-13 00:00:00 | ******************* UNSAT ************* |
| |
| 1)NOTE: PLEASE SEE FAC 61G15-23.002 FOR |
| ALL INFORMATION REQ'D ON A TITLE BLOCK. |
| PLANS DO NOT CONTAIN TITLE BLOCK. |
| PLEASE ALSO SEE FS 471 |
| |
| 2)NOTE: PLEASE SUBMIT AIC RATINGS FOR |
| ALL NEW SERVICE EQUIPMENT BEING INSTALL- |
| ED. MAINS/BRKRS AND PANELS ARE ALL TO BE |
| RATED FOR THE AVAILABLE FAULT CURRENT. |
| PER 110.9/215.5 SHOWN FOR PANEL,NOT MAIN |
| |
| 3)NOTE: PLEASE SEE A-4, REFERENCES 1999 |
| NEC. WE ARE UNDER THE 2002. |
| |
| 4)NOTE: MISSING EQUIPMENT GROUNDING |
| CONDUCTOR FROM MAIN TO PANEL. 250.110, |
| 250.24, SIZE PER 250.122 |
| |
| 5)NOTE: PLEASE SEE NOTE ON RISER MENTION |
| -S WEATHERHEAD TO BE 3' ABOVE ROOF. |
| PLEASE SEE THAT THIS MAY CHANGE DUE TO |
| ACTUAL LOCATION AND CIRCUMSTANCES OF |
| ROOF. FYI. |
| |
| 6 )NOTE: PLEASE LIST THE REQ'D ARC |
| FAULT PROTECTED CURCUIT(S) ON PANEL |
| SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" |
| IN BEDROOMS ARE TO BE PROTECTED , |
| INCLUDING, LTS, RECEPTS, SD'S ETC. |
| |
| 7 )NOTE: PLEASE SEE MISSING REQ'D EGRESS |
| LIGHTING AND/OR CLARIFY EGRESS LIGHTING |
| PER 210.70 AND LS-101 5-8 |
| MISSING AR FRONT DOOR. |
| |
| 8)NOTE: SMOKE DETECTORS ARE REQUIRED |
| INSIDE AND OUTSIDE ALL SLEEPING ROOMS. |
| ON EACH LEVEL OF A MULTI-LEVEL DWELLING |
| UNIT. |
| IN CLOSE PROXIMITY OF STAIRWAYS LEADING |
| TO FLOORS ABOVE AND IN THE VICINITY OF |
| BEDROOMS. |
| PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE |
| A MIN OF 3' FROM BATHROOM DOORS AND |
| 20' FROM COOKING APPL. |
| ABOVE PER:FBC 905.2, NFPA-72 8-1.4 |
| "PLEASE MOVE FIRST FLR CLOSER TO STAIRS" |
| |
| 9)NOTE: PLEASE SHOW ANY LV/ TV/ PHONE |
| ON PLANS AT THIS TIME, OR PLANS WILL BE |
| REQ'D TO BE SUBMITTED AT TIME OF APPLI- |
| -CATION. THIS IS ONLY A NOTE AND IS NOT |
| REQ'D. |
| |
| PLEASE SUBMIT THE ABOVE INFORMATION FOR |
| REVIEW. IF THERE ARE ANY QUESTIONS, |
| PLEASE DO NOT HESITATE TO CALL. |
| |
| DEWEY PALMER |
| ELECTRICAL PLAN REVIEW |
| CITY OF WEST PALM BEACH |
| CONSTUCTION SERVICES DEPT. |
| 561-805-6717 |
| [email protected] |