Date |
Text |
2004-03-11 00:00:00 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| [email protected] |
| |
| 1.)SEPARATE PERMITS REQUIRED. |
| |
| 2.)HISTORIC APPROVAL REQUIRED. |
| |
| 3.)IMPROVEMENTS OVER 50% MUST COMPLY |
| WITH FBC3401.7.2.6; NOTE ON PLAN. |
| |
| 4.)PROVIDE A SURVEY FOR THIS PROPERTY. |
| |
| 5.)THE ENGINEER'S LICENS NUMBER IS TO |
| BE PRINTED ON EACH SHEET, FAC61G15-23.00 |
| 2. |
| |
| 6.)THE STAIR DETAIL 3-A1 DOES NOT |
| COMPLY WITH FBC1007.3.1(1).DO THESE |
| DIMENSIONS INDICATE EXISTING |
| CONDITIONS?SEE FBC1001.3. |
| |
| 7.)A1, SCOPE OF BUILDING WORK |
| INDICATES AN UPSTAIRS KITCHEN.IS THIS |
| CORRECT?NONE IS SHOWN ON THE FLOOR |
| PLAN. |
| |
| 8.)3-A1, HANDRAIL IS TO COMPLY WITH |
| FBC1007.5 (34-38" ABOVE TREAD).ALSO |
| MUST COMPLY WITH FBC1608.2.HOW WILL |
| THE RAIL BE FASTENED TO COMPLY WITH |
| FBC1608.2? |
| |
| 9.)3-A1 SHOWS A STRAP SECURED TO |
| A SLAB, CONFLICTS WITH THE OTHER DETAILS |
| WHICH SHOW WOOD. |
| |
| 10.) FLORIDA STATEWIDE, LOCAL OR SITE |
| SPECIFIC PRODUCT APPROVALS REQUIRED. |
| WWW.FLORIDABUILDING.ORG.PROVIDE A LIST |
| OF ALL CONNECTORS WITH FLORIDA PRODUCT |
| APPROVAL NUMBERS. |
| |
| 11.)CORNER FRAMING DETAIL, APPLICATION |
| CONFLICTS WITH USP CATALOG FOR RS100. |
| ADDRESS. |
| |
| 12.)PROVIDE DESIGN UPLIFT INFORMATION. |
| |
| 13.)SPECIFY ALL CONNECTORS, |
| CONTINUOUS FROM THE FOUNDATION THROUGH |
| THE ROOF, ON ALL DETAILS. |
| |
| 15.)THE DOOR PRODUCT APPROVAL HAS A |
| LIMITATION OF +50/-53.IT APPEARS THAT |
| THE DESIGN PRESSURE FOR THIS OPENING |
| IS -57. |