Plan Review Notes
Plan Review Notes For Permit 04010408
Permit Number 04010408
Review Stop B
Sequence Number 1
Notes
Date Text
2004-02-12 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) FBC* 1804.2.2AREA OF QUESTIONABLE
 SOIL.SUBMIT A GEOTECHNICAL REPORT
 TO VERIFY THE SAFE BEARING CAPACITY OF
 THE SOIL.
  
 3)1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
 REVISE TRUSS ANCHOR SCHEDULE USING
 VALUES THAT DO NOT INCLUDE THE ONE-
 THIRD INCREASE. TRUSS ANCHORS ARE
 REQUIRED TO HAVE STATE OR LOCAL PRODUCT
 APPROVAL.
  
 4)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 5) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL IN ACCORDANCE WITH RULE 9B-72,
 FOR THE BUTT GLASS WINDOW. SPECIFY THE
 TYPE OF GE SILCONE TO BE USED. THE
 HEIGHT DIMENSION ON THE PLAN IS NOT
 CONSISTANT.
  
 6) THE COLLIER GARAGE DOOR REQUIRES
 STATE OR LOCAL PRODUCT APPROVAL IN
 ACCORDANCE WITH RULE 9B-72, INCLUDING
 QUALITY ASSURANCE. SUBMIT FORM FOR LOCAL
 PRODUCT APPROVAL. THE SIZE LIMITATION IN
 THE ENGINEERED DRAWINGS EXCLUDE THE
 SMALLER GARAGE DOOR SHOWN ON THE PLANS.
  
 7) SUBMIT THE APPROVED ENGINEERING AND
 INSTALLATION INSTRUCTIONS FOR THE ENTRY
 DOOR.
  
 8) SPECIFY THE MOUNT TYPE AND ANCHORS
 THAT WILL BE USED FOR THE STORM PANELS.
  
 9) SUBMIT STATE OR LOCAL PRODUCT
 APPROVAL FOR THE TRUSS ANCHORS THAT ARE
 SPECIFIED ON THE PLANS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714