2004-02-10 00:00:00 | DENIED |
| 1.WPB MUNI-CODE FLOOD ZONE |
| PROPERTY IS IN FLOOD ZONE (A) LOWEST |
| FLOOR TO BE 6" ABOVE FLOOD BASE |
| ELEVATION.SUBMIT AN ELEVATION |
| CERTIFICATE. |
| 2.BEFORE A PERMIT TO CONSTRUCT, MAY |
| BE ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE ACTUAL PERMIT |
| SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| 3. THE NOTICE OF COMMENCEMENT SHALL BE |
| RECORDED AT PALM BEACH COUNTY |
| COURTHOUSEAND A COPY SUBMITTED TO THIS |
| OFFICE |
| BEFORE A PERMIT CAN BE ISSUED.BLANK |
| FORMS ARE AVAILABLE FROM THIS OFFICE. |
| 4.RADON FEES DUE |
| 5.WPBFBC 104.2.1.3 |
| QUALITY OF BUILDING PLANS |
| BUILDING PLANS SHALL BE DRAWN TO A |
| MINIMUM 1/8" SCALE UPON SUBSTANTIAL |
| PAPER.DRAWINGS AND SPECIFICATIONS |
| SHALL ALSO COMPLY WITH 104.2.1 |
| 6.PROJECT VALUE TOO LOW OUR ESTIMATED |
| VALUE IS $7845 BASED ON $38.48 PER SF |
| ADJUST PROJECT VALUE ACCORDINGLY |
| 7.FBC 1804.1.3 SHOW FOOTING AND SLAB |
| DETAILS.DRAWINGS TO INCLUDE THE |
| FOLLOWING...DEPTH, GRADE,SIZE, TYPE OF |
| REINFORCEMENT, VAPOR BARRIER USED. |
| 8.SHOW WALL SECTION TO INCLUDE THE |
| FOLLOWING...FRAMING, ROOF FRAMING, |
| HEADERS, TYPES OF STRAPS USED, SHOW |
| METHOD OF TIE-IN TO EXISTING BUILDING. |
| SHOW GRADE LEVEL. |
| 9.HAVE DRAWING SHOW NEW AND EXISTING |
| AREAS.SPECIFY NEW AND EXISTING ROOMS. |
| ARE YOU PUTTING IN NEW WINDOWS AND |
| DOORS. |
| 10. IMPACT PROTECTION REQUIRED FOR NEW |
| WINDOWS. |
| 11.SUBMIT 2 COPIES OF PRODUCT |
| APPROVALS FOR EXTERIOR DOORS, WINDOWS, |
| SHUTTERS AND ROOFING MATERIALS. |
| 12.EXISTING METAL SHED BUILDING |
| IS IT GOING TO BE REMOVED. |
| 13.ROOF SHEATHING SHALL COMPLY WITH |
| FBC 2322.2.25/8" |
| 14.4X FEE STILL DUE FOR WORKING WITH |
| OUT A PERMIT FOR BUILDING AND ELECTRICAL |
| |
| ART LANGE |
| BUILDING PLANS EXAMINER |
| 805-6672 |