2004-02-06 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE CURRENT PRODUCT APPRO
 VAL FOR ALL DOORS, WINDOWS, MULLIONS,
 GLASS BLOCK, ROOF TILE AND ALL STRUC-
 TURAL CONNECTORS UNDER A SEPARATE
 PERMIT AS REQ'D BY BUILDING OFFICIAL.
 2-DETAIL E/4 AND RESIDENTIAL NOTES ON
 DWG #2 DON'T MATCH. REVISE AS REQUIRED
 3-CLARIFY/REVISE TRUSS ANCHOR SCHEDULE.
 4-TYPICAL WALL SECTION DETAIL A/4:
 CLARIFY WHERE ARE TABLES 6 AND 8 FOR
 ROOF FASTENERS TAKEN FROM?. SEE SEC.
 1606.3 FBC 2001 AND SEC. 104.2.1.1
 CITY AMENDMENTS TO FBC 2001.
 5-SHEET #7: A)REVISE/CLARIFY DESIGN
 PRESSURES ACCORDING TO SIZE/LOCATION.
 B)WINDOWS SHOWN ON ELEVATION DON'T MATCH
 WINDOW SCHEDULE.
 C)REVISE ALL NOTES ON FLOOR PLAN & ROOF
 FRAMING PLAN TO REFLECT CHANGE OF WOOD
 BEAM TO CONCRETE BEAM.
 6-SHEET #3: CLARIFY NOTE REGARDING THE
 UPLIFT CALCS AND CONNECTOR SELECTED.