2004-04-24 00:00:00DENIED:
 RESPONSE #2
 DRYER DUCT TO PENETRATE AT PLENUM BOX
 CEILING DIFFUSER.PLEASE INDICATE THE
 HEIGHT OF THE CEILING DIFFUSER.PER
 2001 FBC(M) 504.4, EXHAUST TERMINATION
 SHALL BE NON-SCREENED WITH A BACKDRAFT
 DAMPER.PLEASE PROVIDE DETAIL OF DRYER
 TERMINATION.PROVIDE ADDITIONAL
 INFORMATION ON THE DRYER; (A) COMMERCIAL
 OR RESIDENTAL (B) DOES IT EXHAUST MORE
 THAN 200 CFM (C) DEVELOPED LENGTH
 EXCEEDS 25 FT.
  
 PROVISO:
 PLEASE NOTE, THE DIRECTIONAL BEARING ON
 THE A/C PLANS CONFLICT WITH THE
 ARCHITECTURAL PLANS.
  
 PLAN SHEET AC-4 POOL EQUIPMENT ROOM,
 10 FT SEPARATION REQUIRED BETWEEN THE
 EXHAUST & INTAKE LOUVER.
  
 PLEASE NOTE, PLANS INDICATE EXHAUST &
 FRESH AIR INTAKE TEMINATING IN THE
 CEILING OF THE VEHICULAR DRIVE THRU.
 EXHAUST SHALL TERMINATE AS TO NOT CREATE
 A NUISANCE (2001 FBC(M) 401.5.2).FRESH
 AIR INTAKES SHALL BE LOCATED AS TO NOT
 RECIRCULATE NOXIOUS CONTAMINANTS.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.