Plan Review Notes
Plan Review Notes For Permit 03121324
Permit Number 03121324
Review Stop B
Sequence Number 2
Notes
Date Text
2004-03-06 00:00:00****CORRECTIONS****
  
 SAME COMMENTS APPLY TO #03121335,
 03121308, 03121290, 03121280,03121251.
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE NOTICE OF COMMENCEMENT EXPIRES
 AFTER 90 IF WORK HAS NOT COMMENCED
 REGARDLESS OF THE EXPIRATION DATE ON
 THE NOC.
  
 2.)SHEET S1 SHOWS THE WATERSTOP AT
 3/4" RATHER THAN 1 1/2", SEE PREVIOUS
 LIST #2, CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2111.1.9.ALSO
 REVISE NOTE4, FOUNDATION PLAN NOTES,
 S1.
  
 3.)SEE PREVIOUS LIST, ITEM #3,
 BOTTOM CHORD LIVE LOAD IS REQUIRED TO
 BE 10, 30 IN ATTICS WITH STORAGE,
 FBC1604.1 (SHEET S8, #9).
  
 4.)PRODUCT APPROVALS NOT SUBMITTED
 BEFORE ISSUANCE WILL REQUIRE SEPARATE
 PERMITS WITH ADDITIONAL FEES. HORIZONTAL
 ROLLER NOT SUBMITTED; SLIDING GLASS
 DOOR REQUIRES A SITE SPECIFIC OR LOCAL
 PRODUCT APPROVAL FORM WHICH IS FILLED
 OUT IN ITS ENTIRETY.
  
 5.)SEE PREVIOUS LIST, ITEM #7.PROVIDE
 THE IMPACT FEE STAMP.
  
 6.)PROVIDE A STATEWIDE PRODUCT
 APPROVAL NUMBER FOR CONNECTOR DTC.IF
 ONE IS NOT AVAILABLE, A SITE SPECIFIC OR
 LOCAL PRODUCT APPROVAL IS REQUIRED.
  
 7.)ADDITIONAL FEES DUE.
  
 8.)THE FOLLOWING DETAILS SPECIFY A
 BRAND OF CONNECTOR WITHOUT A MODEL
 NUMBER:1-S2, 1-S8, 1-S12, 2-S12.
 CHECK ALL CONNECTORS.SPECIFY A MODEL
 NUMBER AND PROVIDE A STATEWIDE PRODUCT
 APPROVAL NUMBER.IF ONE IS NOT
 AVAILABLE, APPLY FOR EITHER A SITE
 SPECIFIC OR LOCAL PRODUCT APPROVAL.