2004-06-17 00:00:00********** UNSAT ************
  
 1)NOTE: PLEASE SEE ONLY ONE SET OF PLANS
 WERE SUBMITTED FOR REVIEW.
 PLEASE SUBMIT TWO SETS.
  
 2)NOTE: PLEASE SEE SD'S ARE SHOWN ON
 TWO SEPARATE CIRCUITS. PLEASE SEE SD'S
 ARE REQUIRED TO BE WIRED "INLINE".
 TWO CIRCUITS TO SAME DEVICE?
 NFPA-72/NEC.
  
 3)NOTE: PLEASE SEE GFI IN MASTER BATH
 REQUIRED TO BE W/IN 3' OF SINK.210.52D
 THESE ARE THE FIRST FULL SIZED SCALED
 PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  