Plan Review Notes
Plan Review Notes For Permit 03120894
Permit Number 03120894
Review Stop B
Sequence Number 2
Notes
Date Text
2004-02-17 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SUBMIT A SIGNED AND SEALED COPY OF
 THE SOIL REPORT, INCLUDING BORING LOGS.
  
 4) THE SIZE OF THE ATTIC ACCESS DOES NOT
 COMPLY WITH THE MINIMUM SPECIFIED BY
 FBC 2309.6.
  
 5) 1001.1.3/ 1005.4 ZERO LOT LINE
 EGRESS:WHEN ACCESS TO OR FROM A RE-
 QUIRED EMERGENCY ESCAPE AND RESCUE OPEN-
 ING OF A STRUCTURE TO THE PUBLIC WAY,
 REQUIRES TRANSVERSING A PROPERTY
 (ADJOINING LOT) THAT IS NOT PART OF THE
 ONE WHICH THE STRUCTURE IS LOCATED, AN
 EGRESS EASEMENT THROUGH THE ADJOINING
 PROPERTY IS REQUIRED AND SHALL BE RECORD
 ED IN THE COUNTY RECORDS. THIS EASEMENT
 SHALL BE A MINIMUM OF 3' WIDE AND NOTH-
 ING SHALL BE PLACED WITHIN THE EASEMENT
 AREA WHICH WOULD BLOCK ACCESS TO THE
 EASEMENT AND OR IMPEDE EMERGENCY EGRESS
 FROM THE RESCUE OPENING TO THE PUBLIC
 WAY. NO LANDSCAPING, FENCES OR OTHER
 IMPEDIMENTS SHALL BE INSTALLED IN THIS
 EASEMENT. DUE TO THE RIGHT SIDE OF THE
 STRUCTURE BEING 8 INCHES FROM THE
 PROPERTY LINE, AN EGRESS ESAEMENT IS
 REQUIRED. SUBMIT A COPY OF THE SUB-
 DIVISION COVENENTS SPECIFYING THIS.
  
 6) PROVIDE TABLE 600 CALCULATIONS FOR
 THE EXTERIOR WALL OF THE DINING ROOM AND
 DEN/STUDY AT THE GARDEN COURT, WHICH HAS
 20% OF THE WALL AREA ALLOWED AS OPENINGS
  
 7) SPECIFY THE SIZE OF THE FRENCH DOOR
 SIDELITES IN THE DINING ROOM.
  
 8) SUBMIT MANUFACTURER'S SPECIFICATIONS
 AND UL OR OTHER LISTING INFORMATION FOR
 THE BBQ AND HOOD SPECIFIED AT THE
 COVERED PORCH.
  
 9) SPECIFY THE UPLIFT THAT THE STEEL
 COLUMN ON SHEET S4 IS CAPABLE OF
 RESISTING.
  
 10) 1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREASE IN ALLOWABLE STRESS
 SPECIFIED IN THE MATERIALS SECTION OF
 THE CODE OR A REFRENCED STANDARD SHALL
 NOT BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23. REVISE THE TRUSS ANCHOR
 SCHEDULE TO VALUES THAT DO NOT INCLUDE
 A ONE-THIRD INCREASE IN THE STEEL
 CALCULATIONS. UPDATE ANCHORS TO THOSE
 WITH STATE OF FLORIDA PRODUCT APPROVAL
 AS REQUIRED BY RULE 9B-72. CORRECT
 CONNECTORS THAT ARE SPECIFIED ON SHEET
 S2 FOR INDICATED UPLIFTS WHICH EXCEED
 THE UPLIFT CAPACITIES LISTED IN THE
 SCHEDULE ON S3.
  
 10) SPECIFY THE CONNECTORS/HANGERS FOR
 THE CONNECTION OF THE 2X BEAMS TO THE
 WALL OF THE STRUCTURE AT THE ENTRY.
  
 11)PROVIDE A DETAIL OF THE STEEL COLUMNS
 CARRYING THE 2X BEAMS AT THE ENTRY
 WHICH MEET AT 90 DEGREE ANGLES ON THESE
 COLUMNS.
  
 12) THE ROOF FRAMING PLAN ON S2 DOES NOT
 CORRESPOND WITH THE OTHER PLANS FOR THE
 LOCATIONS OF THE 2X BEAMS AT THE ENTRY.
 PLEASE CORRECT.
  
 13) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
 SUBMIT STATE OR LOCAL PRODUCT APPROVALS
 FOR THE FOLLOWING:
 - DOUBLE INSWING ENTRY DOORS
 - DOUBLE OUTSWING GLAZED DOORS WITH AND
 WITHOUT SIDELITES.
 - SINGLE OUTSWING PANEL DOORS
 - SINGLE HUNG WINDOWS
 - FIXED GLASS WINDOWS (CIRCULAR,ARCHED,
 ETC.)
 - GLASS BLOCK (FIRE RATED)
 - STRUCTURAL MULLIONS
 - OVERHEAD GARAGE DOORS
 - STORM PANELS
 - TRUSS ANCHORS AND CONNECTORS
  
 14) SUBMIT MANUFACTURER'S INSTALLATION
 SPECIFICATIONS AND LISTING FOR ONE HOUR
 FIRE RATED GLASS BLOCK ASSEMBLY.
  
 15) IF STORM PANELS WILL BE USED, SUBMIT
 A KEY PLAN AND INSTALLATION SCHEDULE.
 SPECIFY THE MOUNT TYPE, ANCHOR TYPE AND
 SPACING ON THE INSTALLATION DRAWINGS.
  
 16) A SEPARATE PERMIT WILL BE REQUIRED
 FOR ROOFING. ROOFING CONTRACTOR DID NOT
 SIGN THE APPLICATION.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW