Plan Review Notes For Permit 03120448 |
Permit Number |
03120448 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2003-12-19 00:00:00 | DENIED | | 1. PROVIDE EMERGENCY EGRESS WINDOW IN | | SLEEPING ROOMS WITH A MINIMUM NET CLEAR | | OPENING HEIGHT OF 24INCHES,NET CLEAR | | OPENING WIDTH OF 20 INCHES AND NET CLEAR | | OPENING AREA OF 5.7 SQ.FT. GROUND FLOOR | | OPENINGS ARE PERMITTED TO HAVE A NET | | CLEAR OPENING OF 5.0 SQ.FT. SILL HEIGHT | | SHALL NOT BE MORE THAN 44 INCHES ABOVE | | THE FLOOR. 1997 SBC 1005.4 | | 2. WINDOW SCHEDULE REQUIRED | | FL BLD CODE 2001 SECTION 103.6, | | 1606.1.4, 1707.4 & 3401.7.2.4. | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | SCHEDULE SUMMARIZING & IDENTIFYING | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | SUBMITTED AT TIME OF PERMIT APPLICATION | | TO FACILITATE PLAN REVIEW AND PERMIT | | ISSUANCE. | | 3.SHOW LOCATION OF GATE ON SURVEY | | INCLUDING GATE HEIGHT AND TYPE. | | 4.PERMITS REQUIRED FOR OTHER TRADES. | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|