2004-01-05 00:00:00 | *****CORRECTIONS****** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| [email protected] |
| |
| 1.)A NOTE WAS ENCLOSED INDICATING THAT |
| YOU WANTED FOR THIS PROJECT TO BE A |
| MASTER.THIS MUST BE DONE ON A SEPARATE |
| APPLICATION.SUBMIT TWO COPIES OF |
| DRAWINGS WITH AN APPLICATION. |
| |
| 2.)IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY.THE PLANS MUST BE |
| STAMPED AND THE RECEIPT ATTACHED TO |
| THE APPLICATION.233-5025 |
| |
| 3.)A NOTICE OF COMMENCEMENT MUST BE |
| FILED WITH THE CLERK OF COURTS BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 4.)THE PRINTED NAME OF THE PERSON |
| SEALING THE DOCUMENT (GENZ) AND LICENSE |
| NUMBER IS TO BE INCLUDED ON THE PLAN, |
| AUTHORIZATION NUMBER FOR GENZ |
| ENGINEERING TO BE ON THE TITLE BLOCK, |
| FAC61G15-23.002(2). |
| |
| 5.)ROOF SHEATHING, 3.1, CITY OF WEST |
| PALM BEACH AMENDMENTS TO THE FBC |
| TABLE 2306.1, THE 5' EDGE OF THE GABLE |
| END IS ZONE 3. |
| |
| 6.)ROOF NOTE 03, SHEET 3.1, ROOF |
| SHEATHING IS TO BE A MINIMUM OF 19/22 IN |
| SPANS OVER 16", CITY OF WEST PALM BEACH |
| AMENDMENTS TO THE FBC, REVISED PANEL |
| SPAN TABLE 2307.6B.DETAILS ON THE |
| PLAN SHOW 5/8. |
| |
| 7.)FLOOR PLAN NOTE, 4 (4.1) SHOWS |
| R4.2 INSULATION; R5 REQUIRED PER EN CALC |
| WALL LEGEND SHOWS R3. |
| |
| 8.)SHOW SIZE FOR ATTIC ACCESS, FBC |
| 2309.6. |
| |
| 9.)FIREBLOCKING FOR STAIRS ARE TO BE |
| FULL DEPTH AND AT THE TOP AND BOTTOM |
| STRINGERS OF EACH RUN (STAIR SECTIONS). |
| FBC2305.1.4. |
| |
| 10.)SHEET 1.1, SITE PLAN SHOWS PART OF |
| THE IMPROVEMENT ON LOT 23.SHOULD BE |
| LOTS 7 AND 8.ALSO LEGAL REFERS TO |
| "LOTS 7 AND 5", SHOULD BE "7 AND 8". |
| |
| 11.)SEPARATE PERMITS REQUIRED. |
| |
| 12.)THE BOTTOM CHORD LIVE LOAD FOR THE |
| TRUSSES IS SHOWN AS 0.REFER TO FBC TABLE |
| 1604.1, RESIDENTIAL, DWELLINGS, ATTICS. |
| (TRUSS SHOP DRAWINGS). |
| |
| 13.)STATEWIDE PRODUCT APPROVALS ARE |
| REQUIRED EFFECTIVE OCTOBER 1, 2003. |
| SEE WWW.FLORIDABUILDING.ORG.I HAVE |
| OBTAINED STATE PRODUCT APPROVAL NUMBERS |
| FOR SOME PRODUCTS.PLEASE SUPPLY |
| STATEWIDE APPROVALS FOR THE DOORS, |
| TRACO WINDOWS, SHUTTERS. |
| |
| IN THE FUTURE, WHEN SUBMITTING FOR |
| PERMITS, INCLUDE STATEWIDE PRODUCT |
| APPROVAL NUMBERS WITH ALL TEST REPORTS. |
| IF A PRODUCT DOES NOT HAVE A STATEWIDE |
| PRODUCT APPROVAL, A SITE SPECIFIC WILL |
| BE REQUIRED.IF IT IS DIFFICULT TO |
| DETERMINE WHETHER A PRODUCT IS |
| APPROVED (SUCH AS THE JELDWEN DOORS), |
| PRINT THE COVER SHEET WITH APPROPRIATE |
| PDF FILE CIRCLED FOR VERIFICATION. |