2004-01-26 00:00:00 | DENIED |
| |
| 1) BOTH SETS OF PLANS ARE REQUIRED TO BE |
| STAMPED BY PB COUNTY FOR IMPACT FEES. |
| |
| 2) SUBMIT A SIGNED AND SEALED COPY OF A |
| SUB-SURFACE SOIL TEST REPORT AS REQUIRED |
| BY FBC 1804.2.2. |
| |
| 3)PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| SUBMIT FOR ALL WINDOWS, DOORS, GARAGE |
| DOORS, STORM PANELS, TRUSS CONNECTORS, |
| ETC. THAT IS SPECIFIED ON THE PLANS. |
| |
| 4) THE STRUCTURE IS LOCATED IN AN "A5" |
| FLOOD ZONE AN ELEVATION CERTIFICATE WILL |
| BE REQUIRED BEFORE THE C.O. IS ISSUED. |
| |
| 5) SPECIFY THE SIZES OF THE TWO ATTIC |
| ACCESS OPENINGS ON THE SECOND FLOOR. |
| |
| 6) THE CONDITIONED FLOOR AREA LISTED ON |
| THE ENERGY CALC. FORM DOES NOT AGREE |
| WITH THE A/C AREA LISTED ON THE PLANS. |
| THE FORM IS REQUIRED TO BE SIGNED AND |
| DATED BY THE OWNER/AGENT. |
| |
| 7) SUBMIT MANUFACTURER'S SPECIFICATIONS |
| AND LISTING INFORMATION FOR THE BBQ ON |
| THE LANAI. |
| |
| 8) INDICATE THE BEAM ELEVATIONS (TOB) |
| ON SHEETS S1 AND S2. |
| |
| 9) SPECIFY ON THE PLANS THAT THE WIRE |
| MESH WILL BE SUPPORTED ON APPROVED |
| SUPPORTS AT NO MORE THAN 3'OC PER FBC |
| 1909.3. |
| |
| 10) SUBMIT SIGNED AND SEALED ENGINEERING |
| FOR THE HAMBRO FLOOR SYSTEM. |
| |
| 11) PLEASE UPDATE THE ANCHOR SCHEDULES |
| ON S4 AND S5. FAC RULE 9B-72 REQUIRES |
| TRUSS CONNECTORS TO HAVE STATE PRODUCT |
| APPROVAL. THERE IS NO USP RTPGA |
| CONNECTOR LISTED. SEMCO AND HUGHES ARE |
| NO LONGER IN BUSINESS AND ARE NOT LISTED |
| WITH THE STATE, PLEASE REMOVE REFRENCES |
| TO THEM. |
| |
| 12) 1609.4.3 LOAD REDUCTION. |
| WHEN STRUCTURAL EFFECTS DUE TO TWO OR |
| MORE LOADS IN COMBINATION WITH DEAD LOAD |
| ARE INVESTIGATED IN LOAD COMBINATIONS OF |
| 1609.4.1 OR 1609.4.2, THE COMBINED |
| EFFECTS DUE TO THE TWO OR LOADS MULTI- |
| PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD |
| LOADS SHALL NOT BE LESS THAN THE EFFECTS |
| FROM THE LOAD COMBINATION OF THE DEAD |
| LOAD PLUS THE LOAD PRODUCING THE LARGEST |
| EFFECTS.INCREASE IN ALLOWABLE STRESS SPE |
| CIFIED IN THE MATERIALS SECTIONS OF THIS |
| CODE OR A REFRENCED STANDARD SHALL NOT |
| BE USED WITH THESE LOAD COMBINATIONS |
| EXCEPT THAT A DURATION OF LOAD INCREASE |
| SHALL BE PERMITTED IN ACCORDANCE WITH |
| CHAPTER 23. |
| REVISE TRUSS ANCHOR SCHEDULE WITH VALUES |
| THAT DO NOT INCLUDE THIS STRESS INCREASE |
| SEE LATEST USP CATALOG. |
| |
| 13) SPECIFY FIREBLOCKING ON THE WALL |
| SECTIONS ON D1 AT THE INTERSECTIONS OF |
| THE CONCEALED VERTICAL AND HORIZONTAL |
| SPACES. SEE FBC 2305.1. |
| |
| 14) CLARIFY ON THE STAIR DETAILS ON D2 |
| THAT THE HANDRAILS FOR THE CIRCULAR |
| STAIRS ARE BETWEEN 34" AND 38" ABOVE THE |
| LEADING EDGE OF THE TREADS AS REQUIRED |
| BY FBC 1007.5. |
| |
| 15)PROVIDE (2) PRODUCT APPROVALS, KEY |
| PLANS AND INSTALLATION SCHEDULES |
| INDICATING THE SPECIFIC TYPES OF ANCHORS |
| TO BE USED FOR STORM PANELS. |
| A SEPARATE PERMIT AND FEES WILL BE |
| REQUIRED IF ALL INFORMATION IS NOT |
| SUBMITTED BEFORE PERMIT IS ISSUED. |
| |
| 16) SEPARATE PERMITS WILL BE REQUIRED |
| FOR OTHER TRADES AS THEY WERE NOT SIGNED |
| ONTO PERMIT APPLICATION. |
| |