Plan Review Notes
Plan Review Notes For Permit 03100897
Permit Number 03100897
Review Stop P
Sequence Number 1
Notes
Date Text
2003-10-25 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 1) MORE INFORMATION REQUIRED FOR THE
 CARETAKER 99 FLOOR CLEANING SYSTEM.
 NOTE #5 STATES "THIS SYSTEM REQUIRES 100
 PERCENT OF THE FLOW GENERATED BY THE
 PUMPS WE HAVE LISTED. OPERATION OF ADD-
 ITIONAL WATER FEATURES WILL AFFECT THE
 CARETAKER SYSTEM PERFORMANCE". THE POOL
 SPECIFICATIONS INDICATE A 4' SHEER DES-
 CENT BEING RETURNED TO THE POOL FROM THE
 SAME PUMP. WILL THIS AFFECT THE CARE-
 TAKER SYSTEM PERFORMANCE?
 NOTE #6 STATES "STEPS MUST BE FLARED
 ENOUGH TO INSURE PROPER CLEANING AND
 ACCOMMODATE GUARANTEE. SEE ATTACHED
 BULLETIN". NO ATTACHED BULLETIN FOUND.
 PLEASE CLAIRFY.
 2) NO INTERNAL MEANS OF INTERNAL WATER
 RETENTION SHOWN SO A EXTERNAL HARTFORD
 LOOP WILL BE REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]