2003-10-30 00:00:00 | ****CORRECTIONS***** |
| |
| SAMANTHA THYNG, BUILDING PLANS EXAMINER |
| [email protected] |
| |
| 1.)ADDITIONAL PERMITS REQUIRED. |
| |
| 2.)A NOTICE OF COMMENCEMENT MUST BE |
| FILED WITH THE CLERK OF COURTS BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 3.)PROVIDE AREA CALCULATIONS ON THE |
| PLAN.ADDITIONS OF OVER 25% MUST COMPLY |
| WITH FBC3401.7.2, 2003 AMENDMENT. |
| |
| 4.)THE FLOOR PLAN OVERALL DIMENSION |
| HAS BEEN WRITTEN OVER AND IS NOT CLEAR |
| AND DOES NOT APPEAR TO MATCH THE SURVEY. |
| THE DIMENSIONS MUST ADD UP TO THE TOTAL, |
| AND MUST BE THE SAME AS THE SITE PLAN. |
| |
| 5.)ENERGY CALCS, SIGNED BY BOTH THE |
| PREPARER AND THE OWNER/AGENT, ARE |
| REQUIRED FBC13-103.1.2. |
| |
| 6.)THERE ARE MANY NOTES IN INK ON THE |
| PLAN.THE NOTES MUST BE INITIALED BY |
| THE DESIGNER OF RECORD. |
| |
| 7.)NOTE THAT ON THE WALL SECTION YOU |
| HAVE SPECIFIED R19 UNDER ATTIC, 4.2 ON |
| THE WALL.IF A 600C ENERGY CALC IS |
| SUMBITTED THE MINIMUM INSULATION |
| REQUIRED WOULD BE R30 AND R5 |
| RESPECTIVELY. |
| |
| 8.)CITY OF WEST PALM BEACH AMENDMENTS |
| TO THE FBC1804.1.7, LOWEST BUILDING |
| FLOOR ELEVATION AT THE PERIMITER OF |
| A MONOLITHIC FOUNDATION AT HABITABLE |
| AREAS SHALL BE A MINIMUM OF 4" ABOVE THE |
| FINISHED GRADE.SHOW ON WALL SECTION. |
| |
| 9.)IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY.THE PLANS MUST BE |
| STAMPED AND THE RECEIPT ATTACHED TO THE |
| APPLICATION.233-5025 FOR MORE |
| INFORMATION. |
| |
| 10.) TWO COPIES OF ALL DOCUMENTS MUST |
| BE SUBMITTED.ONE WILL BE RETAINED AT |
| THE CITY AND ONE WILL BE YOUR PERMIT |
| SET. |
| |
| 11.) ADDITIONAL FEES MAY BE DUE.THESE |
| FEES WILL BE DETERMINED AFTER AREA |
| CALCULATIONS ARE SUBMITTED ON THE PLAN. |
| |
| 12.) THIS JOB IS A SUBSTANTIAL |
| IMPROVEMENT TO A RESIDENCE LOCATED IN A |
| FLOOD ZONE. CITY OF WEST PALM BEACH |
| MUNICIPAL CODE REQUIRES THAT THE |
| LOWEST FLOOR BE ELEVATED TO 6" ABOVE THE |
| BASE FLOOD ELEVATION, 94-546.PROVIDE |
| AN ELEVATION CERTIFICATE FOR THE |
| EXISTING HOUSE AND SHOW COMPLIANCE ON |
| THE PLAN. |
| |
| 13.)PROVIDE A SOILS INVESTIGATION |
| REPORT. |
| |
| 14.)A TITLE BLOCK FOR THE ENGINEER |
| IS REQUIRED, FAC61G15-23.001. |
| |
| 15.)GABLE ENDS ARE TO BE STRUCTURALLY |
| CONTINUOUS, FBC2117.1. |
| |
| 16.)A STATEWIDE OR LOCAL PRODUCT |
| APPROVAL IS REQUIRED FOR WINDOWS, DOORS, |
| TRUSS ANCHORS AND IMPACT PROTECTION, |
| FAC9B-72.SEE THE DCA WEBSITE, |
| WWW.DCA.STATE.FL.US/FHCD/FBC/COMMITTEES/ |
| PRODUCT_APPROVAL/1_PRODUCT_APPROVAL.HTM |
| FOR MORE INFORMATION. |
| |
| 17.)THERE IS A NOTE ON THE PLAN TO |
| "MAKE EXIST WINDOW COMPLY W/EGRESS". |
| SHOW HOW THIS COMPLIES WITH FBC1005.4 |
| BY GIVING THE WINDOW SIZE AND TYPE. |
| |
| 18.)IMPACT PROTECTION REQUIRED FBC |
| 1606.1.4. |
| |
| 19.)THERE IS A REFERENCE TO SBC (NOTE |
| AT THE WALL SECTION); CURRENT CODE IS |
| FBC. |
| |
| 20.)ATTIC ACCESS REQUIRED TO COMPLY |
| WITH FBC2309. |
| |
| 21.)PROVIDE A HURRICANE SHUTTER |
| INSTALLATION SCHEDULE IF SHUTTERS ARE TO |
| BE USED, SEE ATTACHED. |