Plan Review Notes For Permit 03100308 |
Permit Number |
03100308 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2003-10-28 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FLORIDA ADMINISTRATIVE CODE | | | | 1) SHT D1 INDICATES THAT A SINK IS LOCA- | | TED WHERE THE NEW SINK WILL BE INSTALLED | | PLEASE CLAIRFY. 104.2.1 | | 2) SUBMIT MANUF. SPECIFICATIONS FOR PUMP | | SYSTEM. PUMP SHALL BE LABLED AND LISTED. | | 3) A GATE VALVE LOCATED ON THE DISCHARGE | | SIDE OF THE CHECK VALVE SHALL BE INSTAL- | | LED IN THE PUMP OR EJECTOR DISCHARGE | | PIPING BETWEEN THE PUMP OR EJECTOR AND | | THE GRAVITY DRAINAGE SYSTEM. | | 4) THE PUMP SYSTEM SHALL TIE INTO A VENT | | LINE. AAV'S ARE NOT DESIGNED FOR POSIT- | | IVE PRESSURE. 916.5.1 & 917.2 | | 5) SEAL FOR ARCHITECT NOT APPROVED. ALSO | | MORE INFORMATION REQUIRED FOR TITLE | | BLOCK. SEE ATTACHED SHEET. 61G1-16.002 | | AND 61G1-16.004 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|