2003-11-03 00:00:00 | BUILDING CHECKLIST: |
| 1-NEED RECORDED NOTICE OF COMMENCEMENT. |
| 2-PROVIDE DETAIL CONNECTION AT TRANSOM |
| WINDOW ON TOP OF GLASS BLOCK AT MASTER |
| BATH. SEC. 104.2.1.2 CITY AMENDMENTS |
| TO FBC 2001. ***NOTE: SEE PRODUCT |
| APPROVAL FOR APPROVED INSTALLATIONS. |
| 3-PROVIDE CONSTRUCTION DETAIL FOR ARCHED |
| OPENINGS AT WINDOWS AND ENTRY PORCH. |
| SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| 4-REVISE DESIGN PRESSURES SPECIFIED FOR |
| DOORS AND WINDOWS OPENINGS. SEE TABLES |
| 1606.2B AND 1606.2E FBC 2001. OR PRO- |
| VIDE ENGINEERING CALCULATIONS FOR |
| DESIGN PRESSURES SHOWN. |
| SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. |
| 5-PROVIDE AIR HANDLING UNIT HANGING |
| DETAILS. SPECIFY ALL FASTENERS. SEC. |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| 6-DESIGN PARAMETERS ON SHEET A3: |
| A)INCLUDE THE ATTIC LIVE LOAD (10PSF OR |
| 30PSF)AS REQ'D BY TABLE 1604.1 FBC. |
| B)WHERE IS THE DESIGN WIND VELOCITY |
| PRESSURE TAKEN FROM. SEE SEC. 6.5.12 |
| OF ASCE 7-98 FOR VELOCITY PRESSURE. |
| C)REVISE THE MEAN ROOF HEIGHT. IT IS |
| TAKEN FROM FINISH GRADE TO THE AVERAGE |
| POINT OF THE HIGHEST ROOF. |
| D)SEE COMMENTS ON SHEET A3. |
| |
| 7-PROVIDE COMPLETE DETAIL FOR INSTALLA- |
| TION OF DOUBLE FRENCH DOORS MULLED |
| TOGETHER. SEE DOOR PRODUCT APPROVAL |
| FOR APPROVED INSTALLATIONS. SPECIFY |
| ALL MATERIALS AND FASTENERS. SECTION |
| 104.2.1.2 CITY AMENDMENTS TO FBC 2001. |
| 8-PROVIDE BBQ UL LISTING AND SPECS. |
| SECTION 2808 FBC 2001. |
| 9-SPECIFY ON PLANS IF GLASS BLOCK IS |
| SAFETY GLASS OR FACE THICKNESS IS NOT |
| LESS THAN 0.25". SEC. 2405.2.2 FBC. |
| 10-PROVIDE STRUCTURAL BUCK DETAIL FOR |
| OVAL AND ARCHED WINDOWS. ALSO, REVISE |
| DOOR AND WINDOW BUCK DETAIL ON SHEET |
| A2 TO COMPLY WITH SEC. 1707.4.4.2 FOR |
| CORRECT BUCK INSTALLATION. |
| 11-DETAIL D/6: SPECIFY ANCHOR EMBEDMENT. |
| SEC. 104.2.1.2 CITY AMENDMENTS TO FBC |
| AND 1606.1.3 FBC 2001. |
| 12-PROVIDE STRUCTURAL BUCK DETAIL FOR |
| ENTRY DOORS. SEE PLANS FOR GAP SHOWN. |
| SPECIFY SIZE OF BUCKS AND FASTENERS. |
| ALSO, SEE SEC. 1707.4.4.2 FOR PROPER |
| BUCK INSTALLATION. |
| 13-STORM SHUTTERS: A)PROVIDE STATE WIDE |
| PRODUCT APPROVAL OR INFORMATION FOR |
| LOCAL PRODUCT APPROVAL. SEE ATTACHED |
| COPY FOR QUESTIONS & ANSWERS REGARDING |
| PRODUCT APPROVAL SUBMITTAL AFTER OCT. |
| 2001. |
| B)PROVIDE KEY PLAN AND COMPLETE INSTALLA |
| TION SCHEDULE. |
| C)CLEARLY MARK ON DRAWINGS SPECIFIC |
| MOUNTING CONDITIONS AND ANCHOR TYPE & |
| SPACING TO BE USED ACCORDING TO THE |
| DESIGN PRESSURES, EDGE DISTANCE, PANEL |
| SPAN, CONNECTION TYPE AND STRUCTURE TO |
| BE ATTACHED TO. |
| |
| 14-SPECIFY WHICH OPENING IS GOING TO BE |
| USED FOR MEANS OF EGRESS THAT COMPLIES |
| WITH SEC. 1005.4.5 FBC 2001. |
| 15-REVISE TRUSS ANCHOR SCHEDULE TO |
| COMPLY WITH SEC. 1609.4.3 FBC 2001 |
| WHICH DOESN'T ALLOW THE STEEL STRESS |
| TO BE INCREASED. PROVIDE ENGINEERING |
| CALCS FOR VALUES OTHER THAN THOSE |
| SHOWN ON PUBLISHED ANCHOR CATALOGUE. |
| 16-PROVIDE ROOF SHEATHING DIAPHRAGM |
| SHOWING NAILING ZONES, FASTENER TYPE |
| AND SPACING. SEC. 2306 CITY AMENDMENTS |
| 17-PROVIDE DETAIL/SPECS FOR CEILING |
| INSTALLATION AT ENTRY AND REAR PORCH. |
| SEE ASTM C926 AND ASTM C1063.SECTION |
| 2504.2 FBC 2001. |
| 18-ENERGY CALCULATIONS: A)COMPLETE ALL |
| INFORMATION ON TOP OF FORM. |
| B)REVISE UNDER ATTIC AREA. SEE SECTION |
| 604.1.A.1. CHAPTER 13 FBC 2001. |
| C)OWNER/AGENT TO SIGN AND DATE FORM TOO. |
| |
| 19-NEED STATE WIDE OR LOCAL PRODUCT |
| APPROVAL FOR ALL DOORS, WINDOWS, |
| MULLIONS, GLASS BLOCK, ROOF FINISHES. |
| SEE ATTACHED QUESTIONS & ANSWERS COPY |
| NOTE: |
| ***ADDITIONALLY MARK ON SUBMITTED DWGS |
| THE SPECIFIC COMPONENTS TO BE USED. EG: |
| IMPACT GLAZING OR NOT, SPECIFIC MULLION |
| SIZE AND ANCHOR SPACING, ETC. |
| 20-SEE COMMENTS ON SHEET A6 AND PLEASE |
| RETURN REVIEWED SET OF DRAWINGS AFTER |
| CORECTIONS ARE DONE TO ORIGINAL CAD |
| DRAWINGS TO EXPEDITE REVIEW PROCESS. |
| 21-VALUATION AND SQUARE FOOTAGE WAS |
| UPDATED. TOTAL PERMIT FEE IS $3532.98. |
| PLEASE BRING PAID RECEIPT TO ADJUST |
| PAYMENTS AND PAY THE BALANCE. |
| |