Plan Review Notes For Permit 03092027 |
Permit Number |
03092027 |
|
Review Stop |
ENG |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2003-10-17 00:00:00 | FAILED: | | 1. PLEASE NOTE THAT A SEPARATE PERMIT | | APPLICATION AND FEES FOR "UNDERGROUND | | UTULITIES AND SITE WORK" IS REQUIRED, | | PLEASE SUBMIT TWO SETS OF CIVIL PLANS | | ONLY WITH REQUESTED INFORMATIONS,(SIGNED | | & SEALED). | | 2. PLEASE SUBMIT TWO SETS OF CIVIL PLANS | | TO THE PUBLIC UTILITIES & ENGINEERING | | ATT: MANNY GONZALEZ 569-8040 EXT 2306. | | 3. A CLEAN OUT WILL NEED TO BE INSTALLED | | IN SANITARY SEWER LATERAL, ON THE | | PROPERTY, AT THE BACK OF SIDEWALK, IF | | NOT ALREADY INSTALLED. | | 4. A G.V. ON DOMESTIC WATER LINE IS | | REQUIRED. | | 5. PLEASE SUBMIT STORM WATER CALC., | | PLEASE INCLUDE PERVIOUS ,IMPERVIOUS | | AND TOTAL SITE AREA . | | 6. CIVIL PLANS SHOULD INCLUDE POLLUTION | | PREVENTION AND EROSION MEASURES. | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|