Plan Review Notes
Plan Review Notes For Permit 03091689
Permit Number 03091689
Review Stop B
Sequence Number 1
Notes
Date Text
2003-10-21 00:00:00DENIED
  
 1) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 2) SUBMIT A PAID RECEIPT FOR THE IMPACT
 FEES.
  
 3) SUBMIT A SUB-SURFACE SOIL REPORT
 INDICATING THE SAFE BEARING CAPACITY OF
 THE SOIL AS REQUIRED BY FBC 1804.2.2.
  
 4) THE ENERGY CALCULATIONS ARE REQUIRED
 TO BE SIGNED BY THE OWNER/AGENT. IN
 ORDER TO TAKE THE CEILING FAN CREDIT ON
 THE ENERGY CALCS, A MINIMUM OF ONE
 CEILING FAN IS REQUIRED IN ALL PRIMARY
 LIVING AREAS. THERE IS NO CEILNG FAN
 SPECIFIED IN THE LIVING ROOM. PLEASE
 INDICATE THE REQUIRED SIZES OF THE FANS
 ON THE PLANS. SEE FBC 13-607.2.A.3.1 AND
 TABLE 6-6.
  
 5) SUBMIT A SIGNED AND SEALED SURVEY.
  
 6) INDICATE ON THE PLANS THE SQFT
 BREAKDOWN OF THE STRUCTURE. (A/C AREA,
 GARAGE, COVERED PORCHES, ETC.)
  
 7) THE GARAGE BUCK DETAIL 3B ON 4S4
 REQUIRES A MINIMUM OF 8X16 BLOCK WITH
 TWO FILLED CELLS WITH ONE #5 ON EACH
 SIDE OF THE GARAGE OPENINGS. THE PLAN
 SPECIFIES ONE REINFORCED FILLED CELL ON
 EACH SIDE OF THE OPENINGS. PLEASE
 CORRECT.
  
 8) THE FOUNDATION PLAN ON SHEET 4
 SPECIFIES WIRE MESH IN THE SLAB AND
 DETAIL 1 ON 4S1 SPECIFIES FIBER MESH
 CONCRETE FOR THE SLAB. PLEASE CLARIFY.
  
 9) THE SECTION AT THE GARAGE DOOR ON 4
 IS MISLABELED. IT SHOULD BE LABELED 3
 ON 4S1.
  
 10) DETAIL 8 ON 4S1 FOR THE SECTION AT
 THE INTERIOR GARAGE WALL REFERENCED ON
 SHEET 4 HAS BEEN CROSSED OUT. PLEASE
 CORRECT.
  
 11) PLEASE MAKE CORRECTIONS TO CONNECTOR
 CHART ON 5B. THE 775# UPLIFT VALUE IS
 FOR 10D NAILS. THE VALUE FOR 10D X 1-1/2
 NAILS 735#. THE USP TAPR216 CONNECTOR IS
 NO LONGER LISTED IN THE CATALOG. SPECIFY
 A CURRENT CONNECTOR. THE LONGER HTT 22
 STRAP WILL BE REQUIRED FOR THE (32) 10D
 NAILS FOR A 5370# UPLIFT. THE UPLIFT FOR
 THE NFM6X16 HAS BEEN REVISED TO 1325# IN
 THE 2003 USP CATALOG. PLEASE REVISE.
 SEE 2003 USP CATALOG.
  
 12) PLEASE PROVIDE MANUFACTURER'S SPECS.
 AND LISTING INFORMATION FOR GAS COOK TOP
 ON COVERED PATIO.
  
 13) SUBMIT MANUFACTURER'S SPECIFICATIONS
 INDICATING THE HORIZONTAL SLIDING
 WINDOW IN BEDROOM #4 MEETS THE EGRESS
 REQUIREMENTS OF FBC 1005.4.
  
 14)FBC 1005.4.5 (GLITCH AMENDMENTS
 JULY 1, 2003) REQUIRES AT LEAST ONE
 MEANS OF ESCAPE FROM A DWELLING WHEN
 SHUTTERED FOR IMPACT PROTECTION. THE
 MEANS OF ESCAPE SHALL BE WITHIN THE
 FIRST FLOOR OF THE DWELLING AND CAN NOT
 BE LOCATED IN A GARAGE. OCCUPANTS IN ANY
 PART OF THE DWELLING SHALL HAVE ACCESS
 TO IT WITHOUT HAVING TO PASS THROUGH A
 LOCKABLE DOOR NOT UNDER THEIR CONTROL.
 INDICATE HOW COMPLIANCE WILL BE
 ACHIEVED.
  
 15) INDICATE THE LOCATION AND SIZE OF
 THE ATTIC ACCESS REQUIRED BY FBC 2309.6.
  
 16) SUBMIT THE ENGINEERED INSTALLATION
 DRAWINGS FOR THE STORM PANELS. SUBMIT A
 KEY PLAN THAT CORRESPONDS TO THE
 INSTALLATION SCHEDULE. THE NUMBERS AND
 SIZES ON THE SHUTTER SCHEDULE DOES NOT
 CORRESPOND WITH THE SHUTTER SCHEDULE ON
 4S4.
  
 17) SUBMIT SITE SPECIFIC ENGINEERING W/
 DETAILED SHOP DRAWINGS, SPECIFICATIONS
 AND RATIONAL ANALYSIS AND/OR TEST DATA
 ASSURING SAFE PERFORMANCE FOR THE BUTT
 GLASS ASSEMBLY IN THE MORNING ROOM. THE
 PRODUCT APPROVAL FOR THE STORE FRONT
 THAT WAS SUBMITTED IS NOT FOR A BUTT
 GLASS ASSEMBLY.
  
 18) THE PRODUCT APPROVAL SUBMITTED FOR
 THE HORIZONTAL SLIDING WINDOWS DOES NOT
 LIST A THREE PANEL WINDOW AS SHOWN FOR
 BEDROOM #4. SUBMIT APPROPRIATE PRODUCT
 APPROVAL.
  
 19) THE REQUIRED WINDLOAD PRESSURES FOR
 THE 36SH WINDOWS IN THE MASTER BEDROOM
 EXCEED THE NEGATIVE PRESSURE OF -43.10
 IN THE PRODUCT APPROVAL FOR 3/16"
 ANNEALED GLASS. SUBMIT APPROPRIATE
 PRODUCT APPROVAL.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714