2004-01-02 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 03091152 |
| ADD: 717 27TH ST |
| CONT: COMPLETE PROPERTY MANAGEMENT |
| TEL: (561)252-8372 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| |
| SECOND REVIEW |
| ACTION: DENIED |
| |
| 1) PLANS, SPECIFICATIONS,REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE DESIGN |
| PROFESSIONAL AND BEING FILED FOR PUBLIC |
| RECORD SHALL HAVE THE SIGNATURE AND |
| SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| TO THE DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| FL ATATE STAT: 61G16.003 ARCHITECTS |
| SOILS REPORT COPIED SIGNATURE NOT |
| ORIGINALNOR IS IT DATED. |
| |
| 2) MINIMUM BUILDING TYPE: TYPE II BUILD. |
| REQUIRES 3 HR BEARING WALLS, PROVIDE |
| ADDTIONAL INFO FOR WALL RATING? |
| |
| 3) THE REQUIRED REAR EGRESSES WILL NEED |
| OPENING PROTECTIVES SECTION 705.1.1.2 |
| EVERY EXTERIOR WALL WITHIN 15 FT. OF A |
| PROPERTY LINE SHALL BE EQUIPPED WITH |
| APPROVED OPENING PROTECTIVES, 3 HR WALL |
| REQUIRES 2 HR OPENING PROTECTIVES. |
| |
| 4) SHEET A-4 INDICATES THE USE OF DECO- |
| RATIVE BRACKETS, SUCH BRACKETS SHALL BE |
| CONSTRUCTED OF APPROVED NONCOMBUSTIBLE |
| MATERIALS OR FIRE RETARDANT TREATED |
| WOOD. F102.2.7 LOCATED IN A "FIRE DIS- |
| TRICT". |
| |
| 5) SHEET A-7 DETAIL 2 INDICATES THE USE |
| ABOVE THE RESTROOMS TO BE LIGHT STORAGE. |
| TABLE 1604.1 LIVE LOADS LIGHT STORAGE |
| TO BE 125 LBS/ SQ. FT. |
| A)106.4.2 STORAGE & FACTORY- INDUS- |
| TRIAL OCCUPANCIES. IT SHALL BE THE |
| RESPONSIBILITY OF THE OWNER, AGENT, |
| PROPIETOR OR OCCUPANT OF GROUP S AND |
| GROUP F OCCUPANCIES, OR ANY OCCUPANCY |
| WHERE EXCESSIVE FLOOR LOADING IS LIKELY |
| TO OCCUR, TO EMPLOY A COMPETENT ARCHI- |
| TECT OR ENGINEER IN COMPUTING THE SAFE |
| FLOOR LOAD CAPACITY. ALL SUCH COMPUTA- |
| TIONS SHALL BE ACCOMPANIED BY AN AFFA- |
| DAVIT FROM THE ARCHITECT OR ENGINEER |
| STATING THE SAFE ALLOWABLE FLOOR LOADS |
| ON EACH FLOOR IN POUNDS PER SQ FT.THE |
| COMPUTATIONS & AFFADAVIT SHALL BE FILED |
| AS A PERMANENT RECORD OF THE BLDG DEPT. |
| B)106.4.3.SIGNS REQUIRED. IN EVERY |
| BUILDING OR PART OF A BUILDING USED FOR |
| STORAGE, INDUSTRIAL OR HAZARDOUS PUR- |
| POSES, THE SAFE FLOOR LOADS, AS REVIEWED |
| BY THE BUILDING OFFICIAL ON THE PLAN, |
| SHALL BE MARKED ON PLATES OF APPROVED DE |
| SIGN WHICH SHALL BE SUPPLIED & SECURELY |
| AFFIXED BY THE OWNER OF THE BUILDING IN |
| A CONSPICUOUS PLACE IN EACH STORY TO |
| WHICH THEY RELATE. SUCH PLATES SHALL NOT |
| BE REMOVEDOR DEFACED, & IF LOST, |
| REMOVED THE OWNER OF THE BUILDING SHALL |
| REPLACE THEM. |