Plan Review Notes For Permit 03081413 |
Permit Number |
03081413 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2003-10-09 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-REVISE SURVEY TO MATCH FLOOR PLANS. | | SEE MASTER BEDROOM. | | 2-GLASS BLOCK AT BATHROOM TO BE SAFETY | | GLASS IF FACE THICKNESS IS LESS THAN | | 0.25". SEC. 2405.2 FBC 2001. | | 3-UPDATE TRUSS ANCHOR SCHEDULE TO COMPLY | | WITH SECTION 1609.4.3 FBC 2001. USE | | USP 2003 CATALOGUE OR SIMPSON HIGH | | WIND-RESISTANT CONSTRUCTION CATALOGUE. | | 2003 WHICH ARE THE ONLY ONES BEING | | UPDATED. | | **NOTE:USE SAME FASTENER TYPE AND NUMBER | | AS PUBLISHED OR PROVIDE ENGINEERING | | CALCULATIONS WHEN FASTENERS DO NOT | | MATCH THOSE ON CATALOGUES. | | 4-REVISE SPECIFICATIONS FOR INSTALLATION | | OF CEILING AT FRONT AND REAR PORCH. | | SEE ASTM C-1063 FOR PROPER NAIL SIZE. | | SEC. 2504.2 FBC 2001. |
|