2003-08-21 00:00:00PROVISO:
  
 1. AHU LOCATED IN ATTIC SHALL COMPLY
 WITH 2001 FBC CHAPTER 13 SUB-SECTION
 610.1.ABC.3.5.2.
  
 2. BATHROOM SHALL HAVE A WINDOW WITH A
 MINIMUM OF 3 SQ FT CLEAR OPENING OR
 BE MECHANICALLY VENTILATED AS PER 2001
 FBC(M) 402.3.1.
  
 3. BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  