Plan Review Notes For Permit 03080874 |
Permit Number |
03080874 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2003-09-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) SANITARY RISER DIAGRAM DOES NOT MEET | | CODE REQUIREMENTS NOR DOES IT REFLECT | | THE FLOOR PLAN. | | A) LAUNDRY SINK SHALL CONNECT DOWN- | | STREAM OF THE BATHROOM FIXTURES. SECTION | | 909.1 | | B) WASH MACHINE SHALL NOT DRAIN PAST | | THE TUB. SECTION 712.3.5 | | C) BIDET IN MASTER BATHROOM NOT VENTED. | | D) SECOND LAV IN MASTER BATH NOT SHOWN | | ON SANT. RISER. | | *********WHEN RESUBMITTING PLANS******** | | PLEASE CLEARLY INDICATE THE REVISION AND | | REMOVE AND REPLACE ANY PAGES AS NECESS- | | ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH | | THE PLANS WHEN RESUBMITTING PLANS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|