2003-08-28 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) SANITARY RISER DIAGRAM DOES NOT RE- | | FLECT THE FLOOR PLAN. | | A) BATH #3 TO BE CONNECTED TO BLDG. | | DRAIN DOWNSTREAM OF W/M - L/T. | | B) BATH #2 TO BE CONNECTED TO THE | | RIGHT SIDE OF THE BLDG DRAIN. | | C) BIDET MISSING FROM THE MASTER BATH. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|