Plan Review Notes
Plan Review Notes For Permit 03080564
Permit Number 03080564
Review Stop P
Sequence Number 1
Notes
Date Text
2003-08-16 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS NOR DOES IT REFLECT
 THE FLOOR PLAN.
 A) BATHROOMS AND SINKS ARE NOT VENTED
 PROPERLY. 1002.3(5)
 B) WATER CLOSETS SHALL NOT BE DOUBLE
 TRAPPED. TRAP IS IN FIXTURE. 1002.1
 C) SINKS ARE NOT SHOWN ON FLOOR PLAN.
 D) FLOOR PLAN ON THE DEMO PLAN INDICAT-
 ES ONE FLOOR. RISER DIAGRAM INDICATES
 TWO FLOORS. PLEASE CLAIRFY.
 E) TUB ARE NOT VENTED. 901.2.1
 2) SUBMIT A NEW FLOOR PLAN FOR COMPARI-
 SON.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]