Plan Review Notes
Plan Review Notes For Permit 03080459
Permit Number 03080459
Review Stop B
Sequence Number 1
Notes
Date Text
2003-09-03 00:00:00BUILDING CHECKLIST:
 1-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOOR WITH SIDELITE SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 B)OVERHEAD GARAGE DOORS.
 C)EXTERIOR SWING DOOR AT GARAGE.
 D)SINGLE HUNG WINDOWS.
 E)WINDOW MULLIONS.
 F)SLIDING GLASS DOORS.
 G)SLIDING GLASS DOORS WITH TRANSOM ABOVE
 SINGLE ASEMBLY AS SHOWN ON PLANS.
 H)ARCHED WINDOWS. SEE PLANS FOR SIZES
 AND SHAPES.
 I)ROOF TILE.
  
 2-PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS OR APPLY FOR A SEPARATE
 PERMIT.
 3-NEED TWO COPIES OF ENERGY CALCULATIONS
 WITH ENGINEER'S ORIGINAL SIGNATURE,
 SEAL, DATE ECT. CHAPTER 471 FLORIDA
 STATUTES.
 4-NEED COMPLETE SOIL TEST REPORT THAT
 INCLUDES FOOTING RECOMMENDATIONS AND
 SOIL BEARING CAPACITY.(ARCHITECT ALSO
 NEEDS THIS INFORMATION IN ORDER TO
 DESIGN THE FOUNDATION). SECTION
 1804.2.2 CITY AMENDMENTS TO FBC 2001.
 5-NEED RECEIPT OF PAID IMPACT FEES.
 6-NEED RECORDED NOTICE OF COMMENCEMENT.
 7-SHEET A-1: A)REVISE DETAIL #38.
 FOOTING TO BE 12" MINIMUM BELOW GRADE.
 SEC. 1804.1.3 FBC 2001. ALSO, INDICATE
 THE 4" MINIMUM ELEVATION ABOVE GRADE
 AS REQUIRED BY SEC. 1804.1.7 CITY
 AMENDMENTS TO FBC 2001. SEE COMMENTS
 ON DRAWINGS.
 8-SHEET A-2: A)SPECIFY SAFETY GLASS
 WHERE REQUIRED BY SEC. 2305.2 FBC.
 SEE PLANS.
 B)IDENTIFY ROOM SHOWN AT BOTTOM OF
 FAMILY ROOM AND BREAKFAST AREA.
 C)CLARIFY BEAMS SPECIFIED FOR COVERED
 PATIO ROOF . ARE THEY ROOF TRUSSES OR
 CONCRETE LINTELS. SEE FRAMING PLANS
 AND DETAILS.
 9-SHEET A-4: A)REVISE BUCK DETAILS. SEE
 SECTION 1707.4.4.2 FBC 2001.
 10-SPECIFY ANCHOR EMBEDMENT AND WASHER
 SIZE REQUIRED FOR GARAGE DOOR BUCK
 DETAIL. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001. SEE PLANS.
 11-SHEET A-5: A)CLARIFY DETAILS 12/A6
 AND 7/A6. THEY DON'T APPLY. SEE THE
 ELEVATION. ALSO, IS NOT CLEAR IF IT'S
 GOING TO BE WOOD TRUSSES OR CONCRETE
 LINTELS.
 B)THERE ARE SOME CONNECTORS THAT NEED
 TO BE SPECIFIED. SEE PLANS.
 12-SHEET A-6:
 A)CLARIFY DETAILS 1/A-6, 7/A-6 AND 12/A6
 THEY DON'T APPLY TO THIS SPECIFC
 CONSTRUCTION. SEE PLANS AND REVISE
 DETAILS AS REQUIRED TO MATCH PLANS.
 13-DETAIL 13/A6 NEEDS TO PROVIDE MORE
 INFORMATION. SEE PLANS.
  
 NOTE:
 PLEASE RETURN REVIEWED SET AFTER THE
 CORRECTIONS ARE DONE TO THE ORIGINAL
 CAD DRAWINGS. DON'T FORGET TO BRING
 BACK STAMPED AND APPROVED PLANS BY THE
 OTHER TRADES.
  
 14-PROVIDE GENERAL SPECIFICATIONS FOR
 FIREBLOCKING AT ALL CONCEALED SPACES.
 SEC. 2305 FBC 2001.
 15-PROVIDE NAILING DIAPHRAGM SHOWING
 THE NAILING ZONES. SEE SECTION
 2306 OF CITY AMENDMENTS TO FBC 2001.
 16-CLARIFY OWNERSHIP OF THIS PROPERTY.
 OWNER INFORMATION GIVEN ON BUILDING
 PERMIT APPLICATION DON'T MATCH
 INFORMATION ON OUR SYSTEM. CLARIFY.