Plan Review Notes
Plan Review Notes For Permit 03071713
Permit Number 03071713
Review Stop E
Sequence Number 2
Notes
Date Text
2004-01-27 00:00:00************** UNSAT *************
  
 1)NOTE: PLEASE HAVE PLANS SIGNED WITH
 A COMPLETE SIGNATURE AS REQ'D PER FS
 481.221.
 PLEASE PROVIDE COPY OF ARCH LICENSE
 CONTAINING SIGNATURE AND /OR DRIVERS
 LICENSE.
 WE HAVE MORE THAN ONE SET OF PLANS WITH
 MORE THAN ONE SIGNATURE. WE WILL BE
 RETAINING ONE COPY OF THIS SET FOR A A
 FILE FOR VERIFICATION.
  
 2)NOTE: PLEASE SEE TITLE BLOCK, PLEASE
 PROVIDE ALL LICENSE #'S AS REQUIRED
 PER FS 481.219 AND FAC 61G1-16.004
  
 3)NOTE: PLEASE MOVE SD IN HALL TO BE
 OUTSIDE BEDROOMS AND INTHE IMEDIATE
 VICINITY, OR ADD ADDITIONAL SD.
  
 4)NOTE: PLEASE SEE ONE OF THE RECEPTS
 IN BEDROOM THAT IS REQ'D ON 2' OF WALL
 SPACE SEEMS TO BE IN A CLOSET?
 210.52
  
 5)NOTE: PLEASE SEE THAT THIS PROJECT IS
 PERMITTED UNDER THE 2002 NEC AS OF
 7/1/03. PLEASE ADJUST NOTE FOR ARC FAULT
 PROTECTION AND LIST REQ'D CIRCUITS ON
 PANELS SCHEDULES. PER 210.12
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]