Date |
Text |
2003-08-08 00:00:00 | BUILDING PLAN REVIEW |
| *******DENIED******* |
| ROBERT BROWN(561) 805 6716 |
| E-MAIL: [email protected] |
| |
| FBC = FLORIDA BUILDING CODE 2001 |
| FBC*= FLORIDA BUILD'G CODE (CITY AMEND) |
| |
| 1) THE NOTICE OF COMMENCEMENT SHALL BE |
| RECORDED AT PALM BEACH COUNTY COURTHOUSE |
| AND A COPY SUBMITTED TO THIS OFFICE |
| BEFORE A PERMIT CAN BE ISSUED.BLANK |
| FORMS ARE AVAILABLE FROM THIS OFFICE. |
| |
| 2) FBC* 11-4.13.6 MANEUVERING CLEARANCES |
| AT DOORS.ON THE PULL SIDE OF DOOR 5, |
| THE LEADING EDGE OF THE DOOR SHALL BE AT |
| LEAST 18" CLEAR OF THE ADJACENY WALL |
| (REF: FIG 25A) |
| |
| 3) FBC 11-4.24.6BREAK ROOM SINK.ANY |
| HOT WATER OR DRAIN PIPES EXPOSED UNDER |
| THE SINK SHALL BE INSULATED OR OTHERWISE |
| CONFIGURED TO PROTECT AGAINST CONTACT. |
| ANNOTATE THE PLANS TO DEMONSTRATE |
| COMPLIANCE. |
| |
| 4) FBC* 104.2.1CONSTRUCTION OF NEW |
| BREAK ROOM.THE KEY PLANS SHOWS THAT |
| THE CONSTUCTION OF THE WALL TO FORM THE |
| NEW BREAK ROOM WILL RESULT IN A NEW ROOM |
| BEING FORMED ADJACENT THE BREAK ROOM. |
| NO MEANS OF ENTRY/EGRESS IS SHOWN FOR |
| THE NEW ROOM.IS THIS ROOM STILL PART |
| OF THE SAME TENANCY AND WHAT IS THE |
| ROOM USE?PLEASE CLARIFY. |
| |
| 5) IF NEW PLAN SHEETS ARE REQUIRED, IN |
| ORDER TO ADDRESS THE ABOVE COMMENTS, THE |
| OLD SHEETS SHALL BE REMOVED AND THE NEW |
| SHEETS INSERTED.ONE COPY OF EACH OLD |
| SHEET SHALL BE INCLUDED WITH THE |
| RESUBMITTAL FOR COMPARISON OF REVISIONS. |
| |
| **QUOTE PERMIT# ON ALL CORRESPONDENCE** |
| |
| END OF REVIEW COMMENTS |
| THE CODE REFERENCES GIVE ADDITIONAL INFO |
| TELEPHONE: (561) 805 6716ROBERT BROWN |
| E-MAIL: [email protected] |