Plan Review Notes For Permit 03071076 |
Permit Number |
03071076 |
|
Review Stop |
B |
Sequence Number |
6 |
|
Notes |
Date |
Text |
2004-06-04 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | REVISION #2, UNDATED | | | | 1.)THIS PERMIT WAS ISSUED WITH A | | PROVISO.PLEASE SUBMIT THE REVISIONS | | AT THIS TIME. | | | | 2.)WHEN RESUBMITTING, DO NOT SUBMIT | | SHEETS WHICH HAVE NOT CHANGED.ALTHOUGH | | A CHANGE IS NOTED ON SHEET A1, I CANNOT | | FIND THE REVISION. | | | | 3.)SHEET A5, SHOW ZONE 3 FOR THE | | HIP ROOF SECTION.ALSO PROVIDE DESIGN | | UPLIFT INFORMATION FOR THE ROOF FRAMING. | | | | 4.)THE SEAL IS REQUIRED TO BE DATED, | | FAC61G15-23.002. |
|