Plan Review Notes
Plan Review Notes For Permit 03071076
Permit Number 03071076
Review Stop P
Sequence Number 1
Notes
Date Text
2003-07-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) POWDER ROOM SHALL NOT DRAIN THROUGH
 THE VENT FOR THE WASH MACHINE/LAUNDRY
 SINK. SECTION 908.3 READS IN PART. WHERE
 THE FIXTURE DRAINS CONNECT AT DIFFERENT
 LEVELS, THE VENT SHALL CONNECT AS A
 VERTICAL EXTENSION OF THE VERTICAL DRAIN
 THE UPPER FIXTURE SHALL NOT BE A WATER
 CLOSET. POWDER ROOM SHALL TIE IN DOWN-
 STREAM OF THE LAUNDRY ROOM FIXTURES. SEE
 RED LINE CORRECTIONS.
 2) DATE REQUIRED ON SIGNATURE AND SEAL
 BY ENGINEER. SEE ATTACHED SHEET FOR ANY
 OTHER REQUIREMENTS PER 61G1-16 SEALS AND
 PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]