Plan Review Notes
Plan Review Notes For Permit 03070965
Permit Number 03070965
Review Stop E
Sequence Number 1
Notes
Date Text
2003-07-23 00:00:00************* UNSAT ****************
  
 1)NOTE: PLEASE PROVIDE NEW DWELLING RM
 USAGE.
  
 2)NOTE: PLEASE SEE 210.52G FOR REQ'D
 RECEPT, TO BE GFI ALSO PER 210.8
  
 3)NOTE: PLEASE SEE ATTACHED COPY OF
 FAC 61G1-16.004 FOR MISSING REQ'D
 INFORMATION FOR ARCH'S TITLE BLOCK.
  
 4)NOTE: PLEASE SEE MISSING RECEPT PER
 210.63 FOR A/C EQUIPMENT.
  
 PLEASE CLARIFY IF MEANS OF DISC REQ'D
 UNDER 440.11 FOR EQUIP IS GOING TO BE
 FROM OUTDOOR PANEL OR NEW DISC'S?
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE NAY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
 PLEASE ALSO NOTE, NO ELECTRICAL TO BE
 W/IN 5' OF POOL.