Plan Review Notes
Plan Review Notes For Permit 03070734
Permit Number 03070734
Review Stop B
Sequence Number 1
Notes
Date Text
2003-09-18 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 1) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2) IMPACT FEES. THE PLANS SHALL BE TAKEN
 TO PALM BEACH COUNTY BUILDING DEPARTMENT
 FOR IMPACT FEE ASSESSMENT. THEY SHALL BE
 STAMPED AT THAT OFFICE AND A COPY OF THE
 PAID RECEIPT SUBMITTED TO THE CITY OF
 WEST PALM BEACH DEPT OF CONSTRUCTION
 SERVICES BEFORE A PERMIT CAN BE ISSUED.
  
 3) FBC* 104.2.2THE SEAL ON THE PLANS
 FOR THE ENGINEER OF RECORD HAS NOT BEEN
 PROPERLY EMBOSSED.
  
 4) FBC* 104.1.5THE SUBMITTED PLANS
 MAKE REFERENCE TO NEW WINDOWS. NOTE THAT
 WINDOW REPLACEMENT IS OUTSIDE THE SCOPE
 OF THIS PERMIT APPLICATION.
  
 5) SUBMIT TWO COPIES OF A PRODUCT
 APPROVAL FOR THE ROOF COVERING.THE
 PRODUCT APPROVAL SHALL BE MARKED TO SHOW
 WHICH ROOFING SYSTEM IS PROPOSED.
  
 6) FBC* 104.2.1THE APPLICATION SHALL
 INCLUDE TWO COPIES OF THE PRODUCT
 APPROVALS FOR THE SHUTTERS AND DOOR.
  
 7) FBC 1606.2.4SHEET 2/2, UTILITY
 SECTION.THE SIMPSON H16-2 TIE IS PRE-
 SLOPED TO SUIT PITCHED RAFTERS.IT IS
 NOT SUITABLE FOR FLAT ROOF RAFTERS.
 AMEND THE DETAIL.
  
 8) FBC 1606.2.4SHEET 2/2, SECTION B-B.
 UH 26 IS NOT A VALID SIMPSON HANGER
 REFERENCE.AMEND THE DETAIL.ALSO, FOR
 THE A34 ANGLE, THE SIMPSON CATALOGUE
 DOES NOT STATE ANY LOAD CAPACITY, IN THE
 DIRECTION OF THE RAFTER LONGITUDINAL
 AXIS, WITH WHICH TO GENERATE A MOMENT TO
 RESIST ROTATION OF THE TRUSS ABOUT THE
 LOWER HANGER UNDER GRAVITY LOAD.
  
 9) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved