2003-09-08 00:00:00 | DENIED |
| |
| 1) A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 2) ONE SET OF ENERGY CALCULATIONS IS |
| FOR ANOTHER MODEL. TWO SETS ARE REQUIRED |
| PLEASE REMOVE THE INCORRECT SET AND |
| SUBMIT TWO COMPLETE SETS. |
| |
| 3) THE REVISED DETAIL 1 ON SHEET 4 IS |
| STILL INCORRECT. FBC 1707.4.4.2 REQUIRES |
| THE BUCK TO EXTEND BEYOND THE INTERIOR |
| FACE OF THE WINDOW OR DOOR FRAME SUCH |
| THAT FULL SUPPORT OF THE FRAME IS |
| PROVIDED. |
| |
| 4) SHEET 2 OF THE PLANS CONTAINS |
| STRUCTURAL INFORMATION AND THE TITLE |
| BLOCK OF THE ENGINEER. THE ENGINEER IS |
| RESPONSIBLE FOR THE STRUCTURAL DESIGN |
| AND IS REQUIRED TO SIGN AND SEAL THIS |
| SHEET. SEE FAC 61G15-23.002. |
| |
| 5) THE NORANDEX SITE SPECIFIC PRODUCT |
| APPROVALS ARE REQUIRED TO BE SIGNED AND |
| SEALED BY THE DESIGNER OF RECORD. IF THE |
| DESIGNER OF RECORD DOES NOT WISH TO SEAL |
| THE FORM, A SIGNED AND SEALED LETTER |
| FROM THE DESIGNER OF RECORD SPECIFYING |
| THE PRODUCT AND SPECIFIC SITE LOCATION, |
| STATING THAT THE PRODUCT HAS BEEN |
| REVIEWED AND IS ACCEPTABLE FOR USE IN |
| THE STRUCTURE. |
| |
| 6) THE PRODUCT APPROVALS FOR THE STORM |
| PANELS ARE ILLEGIBLE. SUBMIT CLEAR |
| COPIES. THE STORM PANEL DRAWINGS ARE |
| STAMPED FOR ONE PERMIT ONLY. THEREFORE, |
| A SIGNED AND SEALED COPY OF THE DRAWINGS |
| IS REQUIRED FOR EACH PERMIT. |
| |
| 7) THE TWO "USP" TA STRAPS LISTED AS A-4 |
| IN THE TRUSS CONNECTOR SCHEDULE WITH |
| (5) 10D X 1-1/2" NAILS AND AN UPLIFT OF |
| 1432# IS INCORRECT. THE UPLIFT VALUE |
| LISTED IN THE 2003 "USP" CATALOG IS |
| 1230#. PLEASE CORRECT. SEE ATTACHED. |
| |
| 8) THE SURVEY INDICATES THAT THE |
| STRUCTURE IS LOCATED IN A "B" FLOOD |
| ZONE. THE CITY'S RECORDS SHOW IT IN AN |
| "AO" FLOOD ZONE. PLEASE SUBMIT CORRECTED |
| SURVEY. |
| |
| 9) SUBMIT CLEAR READABLE COPIES OF THE |
| PRODUCT APPROVALS FOR THE OUTSWING DOOR |
| WITH SIDELITE. |
| |