2003-09-08 00:00:00 | DENIED |
| |
| 1) A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 2) THE SURVEY INDICATES THE STRUCTURE IS |
| LOCATED IN A "B" ZONE. THE CITY'S RECORD |
| INDICATES THAT IT IS IN AN "AO" ZONE. |
| PLEASE CORRECT THE SURVEY. |
| |
| 3) SHEET 2 OF THE PLANS CONTAINS |
| STRUCTURAL INFORMATION AND THE TITLE |
| BLOCK OF THE ENGINEER. THE ENGINEER IS |
| REQUIRED TO SIGN AND SEAL THIS SHEET. |
| SEE FAC 61G15-23.002. |
| |
| 4) THE REVISED DETAIL 1 ON SHEET 4, IS |
| STILL INCORRECT. FBC 1707.4.4.2 REQUIRES |
| THE BUCK TO EXTEND BEYOND THE INTERIOR |
| FACE OF THE WINDOW OR DOOR FRAME SUCH |
| THAT FULL SUPPORT OF THE FRAME IS |
| PROVIDED. |
| |
| 5) THE NORANDEX SITE SPECIFIC PRODUCT |
| APPROVALS ARE REQUIRED TO BE SEALED BY |
| THE DESIGNER OF RECORD. IF THE DESIGNER |
| OF RECORD DOES NOT WISH TO SEAL THE FORM |
| A SIGNED AND SEALED LETTER FROM THE |
| DESIGNER SPECIFYING THE PRODUCT AND THE |
| LOCATION OF THE STRUCTURE, STATING THAT |
| THE PRODUCT HAS BEEN REVIEWED AND IS |
| ACCEPTABLE FOR USE IN THE STRUCTURE. |
| |
| 6) THE PRODUCT APPROVAL FOR THE STORM |
| PANELS ARE ILLEGIBLE. SUBMIT CLEAR |
| COPIES. THE DRAWINGS FOR THE STORM |
| PANELS HAVE A STAMP ON THEM THAT |
| INDICATES THEY ARE FOR ONE PERMIT ONLY. |
| THIS MEANS THAT A SIGNED AND SEALED |
| COPY OF THE DRAWINGS IS REQUIRED FOR |
| EACH PERMIT. SUBMIT A KEY PLAN AND |
| INSTALLATION SCHEDULE FOR THE STORM |
| PANELS. |
| |
| 7) THE PRODUCT APPROVAL FOR THE OUTSWING |
| DOOR WITH A SIDELITE IS ILLEGIBLE. |
| SUBMIT CLEAR COPIES ALONG WITH THE |
| APPROVED DRAWINGS (# S-2188). |
| |
| IF YOU HAVE QUESTIONS, PLEASE CALL. |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |