Plan Review Notes
Plan Review Notes For Permit 03062023
Permit Number 03062023
Review Stop E
Sequence Number 3
Notes
Date Text
2004-08-03 00:00:00********* UNSAT ***********
  
 1)NOTE: SMOKE DETECTORS ARE REQUIRED
 INSIDE AND OUTSIDE ALL SLEEPING ROOMS.
 ON EACH LEVEL OF A MULTI-LEVEL DWELLING
 UNIT.
 IN CLOSE PROXIMITY OF STAIRWAYS LEADING
 TO FLOORS ABOVE AND IN THE VICINITY OF
 BEDROOMS.
 PLEASE ALSO NOTE, SD'S ARE REQ'D TO BE
 A MIN OF 3' FROM BATHROOM DOORS AND
 KITCHENS.
 ABOVE PER:FBC 905.2, NFPA-72 8-1.4
 MISSING SD ON FIRST FLR LEADING OT FLR
 ABOVE. ALSO NEEDS SD TO BE MOVED INTO
 MASTER BEDROOM.
  
 2)NOTE: PLEASE SEE MISSING REQUIRED
 LICENSE #'S PER FAC 61G1-16.004 AND
 FS 481.219
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  