2003-09-15 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03061862
 ADD: 819 HANSEN STREET
 CONT:SUINGLIO ESPEJO
 TEL: (561)305-0244
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 2ND REVIEW
  
 1) THE FOURTH QUESTION FROM THE FIRST RE
 VIEW, SHEET A-1 SHOWS THAT THE CATEGORY
 ISTHEN THERE IS A "B" AND "C", EITHER
 CIRCLE OR "X" OUT THE ONE NOT USED.
 DO THE SAME FOR "SATUS"!!!!!!!!!!!!!
  
 2) SHEET A-2 NOT THE BOTTOM OF THE
 FOUNDATION TO BE 8" BELOW GRADE.WRONG!
 1804.1.3 THE BOTTOM OF THE FOUNDA-
 TION SHALL EXTEND NO LESS THAN 12"
 BELOW FINISH GRADE.
  
 3) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) SLIDING GLASS DOOR
 B) PAIR OF FRENCH DOORS W/ SIDELITES
  
 4) MISSING BEAM INFORMATION, NO LAYOUT
 OF BARS REQUIRED OR SIZE, STIRRUPS ETC?
 SAME COMMENT AS 1ST REVIEW!
  
 5) SECOND FLOOR ALSO MISSING INFORMATION
 AS TO WHAT MATERIAL IT IS MADE FROM?
 NO 2ND STORY FRAMING PLAN, THE SECTION
 PROVIDED FOR FIRST FLOOR REFER TO BOND
 BEAM SCHEDULE? WHERE?
 STRAPING NOTE SEE DETAIL 1/S2? WHERE?
 SAME COMMENTS FROM 1ST REVIEW!!!
 UPLIFT STRAPS FEFER TO ROOF FRAMING
 PLAN? WHERE?
 ROOF NAILING NOT TO CITY W. P. B.
 TABLE 2306.1 6" EDGE/ 6" INTERMEDIATES!
  
 6) 1707.3.1 JOIST HANGERS, FRAMING
 ANCHORS & SIMILAR DEVICES SHALL BE TEST-
 ED IN ACCORDANCE W/ ASTM D 1761 & BE
 LABELED AND LISTED FOR THEIR LOAD CARRY-
 ING CAPACITY.
 INDICATE ON THE ROOF FRAMING PLAN THIS
 INFORMATION.
 1609.4.3 LOAD REDUCTION.
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
  
 7) 1707.4.4.2 TAPERED BUCKS:
 SHALL EXTEND BEYOND THE INTERIOR FACE
 OF THE WINDOW OR DOOR FRAME SUCH THAT
 FULL SUPPORT OF THE FRAME IS SUPPORTED.
  
 8) PROVIDE (2) COPIES OF ENERGY SHEETS,
 ALL PRODUCT APPROVALS TO BE SUBMITTED.
  
 9)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 PLANS REQUIRE COUNTY STAMP REVIEWED!!!!!
  
 10)PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
 JIM WITMER
 BUILDING PLAN REVIEW
 TEL: (561)805-6715
 FAX: (561)659-8026