Plan Review Notes
Plan Review Notes For Permit 03061645
Permit Number 03061645
Review Stop B
Sequence Number 1
Notes
Date Text
2003-07-17 00:00:00******CORRECTIONS******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE PLANS SHOW A FIREPLACE. INCLUDE
 THIS IN THE PROJECT DESCRIPTION OF YOUR
 PERMIT APPLICATION.
  
 2.)ENGINEER TITLE BLOCK REQUIRED,
 FAC61G15-23.002.
  
 3.)THE SQUARE FOOTAGE OF LIVING SPACE
 IS BEING INCREASED (BETWEEN LIVING ROOM
 TO NEW CARPORT, FIREPLACE).THIS IS
 NOT REFLECTED ON THE IMPACT FEE STAMP.
  
 4.)PROVIDE AREA CALCULATIONS -
 EXISTING CONDITIONED AND UNCONDITIONED
 SPACE, PROPOSED, SUBTOTALS, NEW TOTAL.
  
 5.)ENERGY CALCS REQUIRED FBC13-101.2.
  
 6.)SOFFIT VENTS CANNOT "MATCH
 EXISTING", THEY MUST COMPLY WITH
 FBC2309.7.
  
 7.)ON THE WALL SECTION, SHOW THE
 MINIMUM DIMENSIONS ABOVE AND BELOW
 GRADE FOR THE FOUNDATION, FBC1804.1.3,
 CITY OF WPB AMENDMENTS TO THE FBC
 1804.1.7.
  
 8.)PROVIDE A ROOF SHEATHING NAILING
 SCHEDULE, CITY OF WPB AMENDMENTS TO
 THE FBC TABLE 2306.1.
  
 9.)IS THE PROPOSED DRIVEWAY SHOWN ON
 THE SITE PLAN TO BE ON THIS PERMIT? IF
 IT IS, ADD IT TO YOUR APPLICATION.THE
 SITE PLAN AND SURVEY CONFLICT AS TO
 THE DRIVEWAY CONFIGURATION.
  
 10.) THE SITE PLAN SUBMITTED FOR
 ZONING SHOWS ONLY A CARPORT.THE SITE
 PLAN SHOULD SHOW ALL IMPROVEMENTS -
 CARPORT, PORCH, LIVING AREA.REVISE.
  
 11.)SUBMIT TWO COPIES OF THE
 FOLLOWING PRODUCT APPROVALS:
 SHINGLES
 DOORS
 TRANSOM WINDOWS
 IMPACT PROTECTION FOR GLAZING
  
 12.)SHOW THE MINIMUM DIMENSIONS ABOVE
 THE ROOF FOR THE CHIMNEY, FBC2804.2.4.
  
 13.)PROVIDE INFORMATION FOR THE
 FACTORY BUILT FIREPLACE AND CHIMNEY.