2003-07-17 00:00:00 | DENIED BY BUILDING |
| |
| 1) IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY, PLANS STAMPED BY THEM AND |
| COPY OF RECEIPT SUBMITTED TO CITY OF |
| WEST PALM BEACH BUILDING DEPARTMENT, |
| BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| |
| 2)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 3) SUBMIT A SOIL BORING TEST REPORT AS |
| REQUIRED BY CITY AMENDMENTS TO FBC |
| 1804.2.2. |
| |
| 4) THE CONTRACTOR'S SIGNATURE ON THE |
| PERMIT APPLICATION IS NOT NOTARIZED. |
| |
| 5) SAFETY GLAZING IS REQUIRED IN THE |
| BATHROOM WINDOWS PER FBC 2405.2.1. |
| |
| 6) THE 34 ROLLING WINDOW IN THE MASTER |
| BEDROOM MUST COMPLY WITH FBC 1005.4.4 |
| FOR EMERGENCY ESCAPE AND RESCUE. SUBMIT |
| THE CLEAR OPENING DIMENSIONS FOR THIS |
| WINDOW. |
| |
| 7) PROVIDE PRODUCT APPROVALS FOR THE |
| HORIZONTAL SLIDING WINDOW. |
| |
| 8) THE WIRE MESH IN THE SLAB IS REQUIRED |
| TO BE SUPPORTED PER FBC 1909.3. |
| |
| 9) REVISE NOTE #11 ON SHEET 3. INTERIOR |
| DRYWALL FASTENER SPACING FOR 1-3/8" AND |
| 1-1/2" DRYWALL NAILS IS 7" O.C. ON |
| CEILINGS AND 8" O.C. ON WALLS PER FBC |
| TABLE 2306.1. |
| |
| 10) INDICATE ON PLANS THAT THE FINISH |
| FLOOR ELEVATION AT HABITABLE AREAS IS A |
| MINIMUM OF 4" ABOVE FINISH GRADE PER |
| CITY AMENDMENTS TO FBC 1804.1.7. |
| |
| 12) SPECIFY ON PLAN THAT THE BOTTOM OF |
| FOOTINGS IS REQUIRED TO BE A MINIMUM OF |
| 12" BELOW FINAL GRADE PER FBC 1804.1. |
| |
| 13) PROVIDE A BUCK DETAIL FOR THE SIDE |
| SWING EXTERIOR FRONT DOOR. |
| |
| 14) SUBMIT A KEY PLAN AND INSTALLATION |
| SCHEDULE FOR THE STORM PANELS. INDICATE |
| THE CONNECTION TYPE AND ANCHOR TYPES ON |
| THE PRODUCT APPROVAL THAT WILL BE USED. |
| |
| 15) THE OWNER/AGENT IS REQUIRED TO SIGN |
| AND DATE THE ENERGY CALCULATION FORM |
| 600A. |
| |