2004-05-17 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 03060499 |
| ADD: 4017 PINEWOOD AV |
| CONT: (PLAN REVIEW) |
| TEL: (561)644-7416 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| |
| 5TH REVIEW |
| ACTION: DENIED |
| |
| 1) COMMENT# 5 FROM PREVIOUS REVIEW, |
| SINCE THERE IS NO ESTABLISHED PROPERY |
| LINE ON THE NORTH SIDE OF THE BUILDING |
| THE SAME ISSUE OF OPENING PROTECTIVES |
| WILL BE AN ISSUE. PLANS INDICATE ASSUMED |
| PROPERTY LINE OF 10'-6" AWAY FROM THE |
| BUILDING DOORS, THEY WILL REQUIRE 3/4 HR |
| PROTECTIVES. |
| RESPONCE : STORM SHUTTERS ARE CALLED FOR |
| SEE SHEET A4.1. |
| |
| THE SHEET A4.1 ACTUALLY HAS RED LINED |
| NOTES, " PROVIDE STORM SHUTTERS TO MEET |
| F.B.C. IMPACT RESISTANT REQUIREMENTS AT |
| ALL WINDOWS THIS ELEVATION". |
| NO MENTION OF GLAZED DOORS. |
| |
| 2) COMENT# 6 FROM PREVIOUS REVIEW, |
| PROVIDE FIRE SPRINKLER PLANS REQUIRED BY |
| TABLE 500, ALLOWABLE AREA INCREASE FOR |
| FIRE SPRINKLERED BUILDINGS AND 903.7.2.4 |
| EVERY AUTOMATIC FIRE SPRINKLER SYSTEM |
| REQUIRED BY THIS CODE SHALL CONFORM TO |
| NFPA 13.903.2 REQUIREMENTS. |
| THESE PLANS SHALL BE PART OF THE BUILD- |
| ING SET OF PLANS REQUIRED FOR ISSUANCE |
| OF THE BUILDING PERMIT. |
| |
| 3) COMMENT# 9 FROM PREVIOUS REVIEW, |
| THIS DEALS WITH THE REQUIRED PRODUCTS |
| FOR COMPONENTS AND CLADDING FOR AN |
| ENCLOSED BUILDING. |
| FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A) WINDOWS, FIXED & OPERATABLE |
| B) EXTERIOR DOORS, SOLID & GLAZED |
| C) LOUVERS |
| D) ROOF ASSEMBLIES, ALL TYPES USED |
| E) STORM SHUTTERS |
| F) TRUSS ANCHORS |
| PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| WHEN THE CONTRACTOR COMES IN FOR PERMIT |
| EITHER THE PRODUCT TESTING REPORTS FOR |
| THE LISTED ITEMS ARE TO BE PRESENT, OR |
| THEY MAY BE SUBMITTED LATER BUT UNDER |
| A SEPERATE PERMIT WITH ASSOCIATED FEES. |
| CONTRACTOR TO SUBMIT IN LETTER FORM IF |
| THEY DESIRE TO SUBMIT THESE APPROVALS |
| LATER. LETTER MUST BE SIGNED BY THE |
| QUALIFIER OF THE COMPANY AND NOTIRIZED. |
| |
| NOTE: THIS IS A THRESHOLD BUILDING, |
| REQUIRING 3 SETS OF ALL DOCUMENTS, PLANS |
| PRODUCT APPROVALS, ETC. |
| |