2004-05-06 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 03060499 |
| ADD: 4017 PINEWOOD AVE |
| CONT: PLAN REVIEW-TBA |
| CONTACT: JEFF HALVERSON |
| TEL: (561)659-8040 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| |
| 1) THE DRAWINGS ARE "RED LINED" BUT THE |
| DESIGN PROFESSIONAL WHO DESIGNED THE |
| PROJECT NEVER "SIGNED AND DATED" THE RED |
| LINED CHANGES. PLEASE HAVE THE DESIGN |
| PROFESSIONAL WHO DESIGNED THE PROJECT |
| SIGN OR CEATE NEW PAGES WITH CHANGES |
| CLOUDED OR DELTAS, SIGNED AND SEALED. |
| |
| 2) COMMENT 3A FROM LAST REVIEW:SHEET 4.1 |
| WEST ELEVATION 4'-0" DIA. FIXED WINDOW |
| SHALL BE 45 MINUTE OPENING PROTECTIVES, |
| SHOP DRAWING AFTER THE PERMIT IS ISSUED |
| WILL BE FINE. |
| THE OTHER ISSUE WILL BE LARGE MISSLE IM- |
| PACT, SHEET A-8 WINDOW (F) PROVIDE |
| MISSLE IMPACT HEAVY GUAGE GALVANIZED |
| EXPANDED METAL, PROVIDE PRODUCT TESTING, |
| 140 MPH WINDS, EITHER STATE APPROVAL OR |
| SITE SPECIFIC. |
| |
| 3) COMMENT 3B PREVIOUS REVIEW: |
| SHEET A2.1 INDICATES DOOR OPENING NUMBER |
| 126 WHICH HAS A LOUVER, 705.1.1.2 WILL |
| REQUIRE A 45 MINUTE PROTECTIVE. |
| |
| 4) COMMENT 3C FROM PREVIOUS REVIEW: |
| DISCREPANCY SEE SOUTH SERVICE YARD SHEET |
| A2 INDICATES DOOR # 110 14-6 FROM PROPER |
| TY LINE VS A2.2 14'-1", THE DISCREPANACY |
| IS HOW FAR THE FRONT OF THIS WALL IS |
| FROM THE PROPERTY LINE!!! |
| |
| 5) SINCE THERE IS NO ESTABLISHED PROP- |
| ERTY LINE ON THE NORTH SIDE OF THE BUILD |
| ING THIS SAME ISSUE OF OPENING PROTEC- |
| TIVESWILL BE A ISSUE, PLANS INDICATE ASS |
| UMED PROPERTY LINE OF 10'-6" AWAY FROM |
| THE BUILDING. DOORS WILL REQUIRE 3/4 |
| HR PROTECIVE, 2HR RATED WALL. PLANS INDI |
| CATE THE FIRE RATING BUT HOW WILL THE |
| LARGE MISSLE IMPACT RATING BE ACHIEVED? |
| GLASS CAN NOT BE 45 MINUTE FIRE RESIS- |
| TANT AND LARGE MISSLE IMPACT RATED AT |
| THE SAME TIME. |
| |
| 6) COMMENT 6 FROM PREVIOUS REVIEW: |
| PROVIDE FIRE SPRINKLER PLANS REQUIRED BY |
| TABLE 500 ALLOWED AREA INCREASE FOR |
| SPRINKLERED BUILDINGS AND 903.7.2.4. |
| EVERY AUTOMATIC SPRINKLER SYSTEM |
| REQUIRED BY THIS CODE SHALL CONFORM TO |
| NFPA 13.903.2 REQUIREMENTS. |
| |
| PROVISO:PLANS NOW INDICATE THAT THERE |
| WILL BE NO BLEACHERS IN THIS GYM!!!!! |
| **REMOVE BLEACHERS FROM SHEET E3.** |
| |
| PROVISO: SHOP DRAWINGS FOR ACCESSIBLE |
| SIGNAGE AND TO BE INSTALLED BEFORE THE |
| CERTIFICATE OF OCCUPANCY WILL BE ISSUED. |
| |
| 7) COMMENT 14 PREVIOUS REVIEW DOOR SCHED |
| ULE HADN,T INDICATED WHAT DOORS REQUIRE |
| PANIC HARDWARE.SHEET A8 NOW DOES INDI- |
| CATE PANIC HARDWARE, DOORS 1/116 & 7/116 |
| INDICATE PANIC HARDWARE, AS IN THE MEET- |
| ING THESE DOORS LEAD TO GATED SERVICE |
| YARDS, NOT A EGRESS. 9035.1.2 FIRE ALARM |
| BOXES ARE NOT TO BE MORE THAN 5'-0" |
| FROM AN EXIT, REMOVE THE STROBE AND |
| HORN FROM LS1. |
| |
| 8) COMMENT 13 FROM 1ST REVIEW: |
| SHEET A6.3 WALL SECTIONS, DETAILS DO NOT |
| GIVE STUD SPACING, GUAGE, NOR THE WIRE |
| SIZE & SPACING, HOW ARE STUDS TO BE |
| SECURED TO THE STRUCTURE ABOVE. |
| |
| 9) FL BLD CODE 1606.1.5: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A) WINDOWS FIXED & OPERATABLE |
| B) EXT DOORS, SOLID & GLAZED |
| C) LOUVERS |
| D) ROOF ASSEMBLIES, ALL TYPES USED |
| E) STORM SHUTTERS |
| F) TRUSS ANCHORS |
| *******IMPORTANT******** |
| PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| |
| BUILDING PLAN REVIEW |
| JIM WITMER |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |