2003-06-16 00:00:00 | PLAN REVIEW NOT A PERMIT APPLICATION. |
| |
| THIS WILL BE A THRESHOLD BUILDING AS |
| DEFINED IN FBC 105.13 AND WILL REQUIRE |
| A THRESHOLD INSPECTOR AND A THRESHOLD |
| INSPECTION PLAN PRIOR TO PERMITTING. |
| |
| SHEET LS-1 DECLARES A NET ASSEMBLY AREA |
| OF 10200 SQUARE FEET.THE |
| LOUNGE/RECEPTIONAREA SHOULD BE |
| INCLUDED, TOO. |
| |
| SHEET LS-1 DECLARES FBC TABLE 600 AS NOT |
| APPLICABLE TO THE WEST PROPERTY LINE. |
| THAT IS A COMMON PROPERTY LINE AND TABLE |
| 600 IS APPLICABLE.THE OPENINGS SHOWN |
| ON SHEET A4.1 ARE NOT ALLOWED BY FBC |
| T-600 AND THE WALL IS REQUIRED TO BE OF |
| 3 HOUR FIRE RESISTIVE CONSTRUCTION. |
| |
| SHEET LS-1 EGRESS CALCULATIONS.USE FBC |
| TABLE 1004 NOT SECTION 1024.2.6. |
| |
| THE MAXIMUM TRAVEL DISTANCE FOR GROUP A2 |
| IS 200' NOT 250'.FBC T-1004. |
| |
| THE TWO HOUR WALL DESIGN ON SHEET LS-1 |
| AND A8 CITES U 906.THIS DESIGN |
| INCORPORATES A 6" PROPRIETARY BLOCK NOT |
| SHOWN AS BEING USED IN THE STRUCTURAL |
| OR ARCHITECTURAL PLANS.PLEASE CLARIFY. |
| |
| THE PLANS DO NOT SHOW PROVISIONS FOR |
| OCCUPANT CONTENT SIGNS IN ACCORDANCE |
| WITH FBC 403.1.2.3. |
| |
| LS-1 NOTES 75' AS A PERMITTED COMMON |
| PATH OF TRAVEL.SEE FBC 1019.1.3. |
| |
| THERE IS NO INFORMATION ON THE PLANS FOR |
| THE DOOR HARDWARE.SEE FBC 1012 AND |
| 1019.7. |
| |
| THERE ARE NO DETAILS OR SPECIFICATIONS |
| FOR THE BLEACHERS SHOWN THROUGH OUT THE |
| PLANS. |
| |
| SHEET A2.1 CALLS OUT SECTIONS 4/8.2 AND |
| 5/8.2 AND THERE IS NO SHEET 8.2. |
| |
| SECTION A/4.3 TAKEN FROM SHEET A3.1 IS |
| NOT CONGRUENT. |
| |
| SHEET A4.3 DETAIL (3).WHERE IS THIS |
| USED? |
| |
| SHEET A6.3, WALL SECTION (7).SHOW A |
| CONSTRUCTION DETAIL FOR THE SUSPENDED |
| GYP BOARD CEILING INCLUDING |
| CONNECTIONS, SIZES, SPACING, MATERIALS |
| AND DIMENSIONS.FBC 104.2. |
| |
| SHEET S4 MASONRY NOTES #4 AND S3 MASONRY |
| NOTES #2 DO NOT AGREE. |
| |
| SHEET S4 CALLS OUT SSTD 12-97, THE FBC |
| INVOKES 12-99.SEE FBC 35. |
| |
| SHEET FP-1, PLEASE NOTE THE CODE |
| EDITIONS USED, IE NFPA 13-99. |