Plan Review Notes For Permit 03060496 |
Permit Number |
03060496 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2003-08-21 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 03060496 | | ADD: 215 S OLIVE AVE | | CONT: RAYMOND NORDINE | | TEL: (561)252-1662 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | ACTION: DENIED | | | | 1) MEANS OF EGRESS- FOURTH FLOOR IS THE | | BUSINESS OCCUPANCY, MEETS THE REQUIRE- | | MENT FOR SINGLE EXIT SECTION 1020.1. | | | | PROBLEM: 1026.1 SINGLE EXIT RESIDENTIAL, | | FOR R-1, R-2, | | 1) MUST MEET THE MAXIMUM TRAVEL DIS- | | TANCE TO REACH AN EXIT FROM THE ENTRANCE | | DOOR TO ANY DWELLING UNIT SHALL NOT | | EXCEED 30 FEET.OK | | 2) MAXIMUM NUMBER OF UNITS PER FLOOR | | SHALL NOT EXCEED (4). OK | | 3) MAXIMUM GROSS AREA SERVED BY THE | | DWELLING UNIT DOES NOT EXCEED 3,500 FT. | | PER FLOOR. OK | | 4) MAXIMUM BUILDING HEIGHT SHALL BE | | ONE STORY ABOVE THE LEVEL OF EXIT | | DISCHARGE. THIS IS THE AREA WHERE WE DO | | NOT MEET THE CODE, MAKING A SECOND MEANS | | OF EGRESS REQUIRED.THE CIRCULAR STAIRS | | MAY MEET THE SECOND MEANS OF EGRESS, | | BUT NOT WITH THE RISE INDICATED ON SHEET | | A.2 NOTE# 5, RISE OF 8.92" EACH RISER. | | | | TO BE USED AS A MEANS OF EGRESS | | ALL SECTIONS OF 1007.8.2.1 (1-6) MUST BE | | MET! PROVIDE UPDATED INFORMATION. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|