Date |
Text |
2003-06-06 00:00:00 | BUILDING DENIED |
| |
| 1) A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 2) SUBMIT RECEIPT FOR IMPACT FEES. |
| |
| 3) SUBMIT A SOIL BORING TEST REPORT. |
| |
| 4) REVISE/CLARIFY NOTE #1 ON SHEET A-5. |
| HANDRAIL AND GUARDRAIL ARE NOT THE SAME. |
| SEE FBC 1007.5.1 FOR HANDRAIL HEIGHT. |
| |
| 5) REVISE NOTE #7 UNDER SOFFIT SPECS. TO |
| INDICATE THAT 3/8" HIGH RIB LATH IS |
| REQUIRED TO BE ATTACHED AT EVERY RIB |
| (4"O.C.) PER ASTM C 1063. ALSO NOTES 4 |
| AND 5 ARE THE SAME. |
| |
| 6) SPECIFY THE LENGTH/EMBED DEPTH OF THE |
| 1/2" DIA. EXPANSION ANCHOR ON THE WOOD |
| FRAME TO CONCRETE WALL DETAIL ON A6. |
| UPDATE THE SEMCO STUD TO PLATE CONNECTOR |
| TO "USP" SPT OR SPTH OR EQUAL. |
| |
| 7) CLARIFY THE C2 COLUMN SPECIFIED ON |
| S1. THE SCHEDULE LISTS (2) 2X4 AND THE |
| NOTE ON THE FOUNDATION PLAN SPECIFIES |
| (3). |
| |
| 8) THE 2003 USP CATALOG DOES NOT LIST A |
| TP6X STUD TO PLATE CONNECTOR. PLEASE |
| REVISE DETAILS 3/S1 AND E/S3 TO "USP" |
| SPT OR SPTH OR EQUALS. |
| |
| 9) THE STEEL COLUMN AT THE GARAGE IS |
| SHOHN ON THE LOWER ROOF PLAN ON S-2 |
| CARRYING CARRYING (2) GIRDERS AT 90 |
| DEGREE ANGLES. DETAIL 4 DOES NOT ADDRESS |
| THIS CONFIGURATION. PLEASE CLARIFY. |
| |
| 10) SPECIFY THE FLOOR TRUSS TO CONC. |
| WALL CONNECTOR ON DETAIL 1/S2. |
| |
| 11) CLARIFY THE CONNECTION OF THE (2) |
| GIRDER TRUSSES ON S2 THAT MEET ON AN |
| ANGLE AT THE CORNER ABOVE THE FAMILY |
| ROOM AND NOOK. DETAIL D/S2 IS SPECIFIED. |
| |
| 12) REVISE THE ROOF SHEATHING NAILING |
| DIAGRAM ON S3 TO INDICATE THAT THE |
| GABLES AT THE ENTRY AND GARAGE ARE |
| ZONE 3. |
| |
| 13) REVISE TRUSS CONNECTOR UPLIFT |
| CAPACITIES TO VALUES THAT DO NOT INCLUDE |
| A ONE-THIRD INCREASE IN THE STEEL |
| CALCULATIONS. THIS INCREASE IS NOT |
| ALLOWED BY FBC 1609.4.3. SEE 2003 USP |
| CATALOG. |
| |
| 14) THE PRODUCT APPROVALS FOR THE |
| STRUCTURAL MULLIONS EXPIRED 5/1/03. |
| |
| 15) THE LOCATION OF THE JOB IS REQUIRED |
| ON THE SITE SPECFIC ENGINEERING FORM. |
| |
| 16) THE OWNER AND CONTRACTOR INFORMATION |
| ON THE ENERGY CALCS. AND THE APPLICATION |
| DO NOT MATCH CITY AND COUNTY RECORDS. |
| PLEASE CORRECT. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |