Date |
Text |
2003-06-30 00:00:00 | BUILDING PLAN REVIEW |
| PERMIT: 03052070 |
| ADD: 400 NORTHPOINT PARKWAY/ 409 |
| CONT: LTI DEVELOPMENT |
| TEL: (561)478-1841 |
| FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| |
| ACTION: DENIED |
| |
| NOTE: |
| 1020.1 SINGLE EXIT BUSSINESS MEETS THE |
| REQUIEMENTS. |
| |
| 1027.1.1 STORAGE, SINGLE EXIT MEETS THE |
| REQUIREMENTS. |
| |
| PROBLEM: CHANGE OF ACCESSORY OCCUPANCIES |
| THE MAIN OCCUPANCY BEFORE WAS STORAGE |
| BECAUSE OF THE SIZE OF THE WAREHOUSE |
| WITH THE OFFICE BEING THE ACCESSORY OCC- |
| UPANCY, (704.1.2.1). |
| |
| NOW 704.1.2.2(4) ROOMS OR SPACES USED |
| FOR CUSTOMARY STORAGE OF NONHAZARDOUS |
| MATERIALS IN A GROUP B WITH IN AGGREGATE |
| DO NOT EXCEED 1/3 OF THE MAJOR OCCUPANCY |
| FLOOR AREA IN WHICH THEY ARE LOCATED. |
| BUSINESS 3099SQ FT |
| STORAGE2254SQ FT |
| |
| TABLE 704.1 STORAGE S2 LOW HAZARAD 2HRS. |
| PROVIDE UL LISTING FOR 2 HR WALL. |
| |
| LOOK FOR COMMENTS BY THE OTHER PLAN |
| REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| ON THE APPLICATION, PLANS, OR ATTACHED |
| SEPARATELY. WHEN RESUBMITTING PLANS |
| PLEASE CLEARLY INDICATE THE REVISION AND |
| REMOVE AND REPLACE ANY PAGES AS NECESS- |
| ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH |
| THE PLANS WHEN RESUBMITTING PLANS. A |
| TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW NUMBER, WITH A DESCRIPTION OF THE |
| REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN |
| BE FOUND, WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| JIM WITMER |
| BUILDING PLAN REVIEW |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |