Plan Review Notes For Permit 03051835 |
Permit Number |
03051835 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2003-07-07 00:00:00 | ****PROVISO****** | | 1)R-3 EGRESS DOOR/ 32" CLEAR: | | 1003.2.1. THE WIDTH OF THE MEANS OF | | EGRESS SHALL BE DETERMINED FROM THE | | OCCUPANTS SERVED IN ACCORDANCE WITH | | TABLE 1004.R-3 MINIMUM CLEAR OPENING OF | | EXIT DOOR IS 32". 1012.1.1 EGRESS DOORS | | USED IN THE EXIT ACCESS SHALL PROVIDE A | | CLEAR OPENING OF NOT LESS THAN 32" WIDE. | | 1012.1.7 REQUIRED EXIT DOORS SHALL BE | | OPENABLE FROM THE INSIDE WITHOUT THE USE | | OF A KEY OR TOOL, OR SPECIAL KNOWEDGE OR | | EFFORT. MANUALLY OPERATED FLUSH BOLTS OR | | SURFACE BOLTS ARE PROHIBITED. ALL HARD- | | WARE MUST BE DIRECT ACTING REQUIRING NO | | MORE THAN ONE OPERATION. | | | | 2) STORM SHUTTERS: | | A) MISSING KEY PLAN | | B) BOTTOM FASTENER CAULK-IN, THE VALUE | | TAKEN IS FOR CONCRETE, NOT CEMENT BLOCK! | | THIS FASTENER MAY NOT BE USED IN BLOCK, | | OR IF THIS IS USED IN FILLED CELL, THE | | CAULK-IN MUST BE IN 2500 PSI CONCRETE | | (FILLED CELL). OTHER ALTERNATIVE IS A | | DIFFERENT FASTENER FOR BLOCK. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|