Plan Review Notes For Permit 03051826 |
Permit Number |
03051826 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2003-06-14 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 FUEL GAS | | | | 1) SHT 1, SANITARY RISER DIAGRAM DOES | | NOT MEET CODE OR REFLECT THE FLOOR PLAN. | | FLOOR PLANS SHOW W/C AND SHOWER, BUT THE | | RISER DIAGRAM SHOWS NO W/C AND AN EXTRA | | TUB. MASTER BATH BIDET NOT VENTED. 908.3 | | BATH #1 ONLY THE FIXTURES FROM THE BATH | | ROOM GROUP SHALL DRAIN INTO THE WET VENT | | OF THE BATHROOM FIXTURES. THE TUB AND | | LAUNDRY SHALL TIE INTO BRANCH LINE PRIOR | | TO BATH #1, AND LAUNDRY SINK AND WASH | | MACHINE SHALL REQUIRE SEPARATE STACKS AS | | THEY ARE ON DIFFERENT WALLS. BATHS #'S | | 2 & 4 SHOW TUBS ON FLOOR PLAN BUT HAVE | | SHOWERS ON RISER DIAGRAM. SEC 1-4.2.1 | | SEC 909.1 | | 2) SHT 2 SHOWS GAS RANGE IN KITCHEN. | | SEPARATE PLANS & PERMIT REQUIRED FOR GAS | | SECTION 104.2.1 | | (SEE ATTACHED SHEET FOR BATH #1 - LAUN- | | DRY ROOM RISER EXAMPLE) | | | | REVIEW BY KEN STEVENS | | (561) 659-8096 EXT 8377 | | (561) 805-6721 | | FAX (561) 653-2692 |
|