Plan Review Notes For Permit 03051786 |
Permit Number |
03051786 |
|
Review Stop |
B |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2003-07-10 00:00:00 | ********BUILDING PROVISO******* | | PERMIT: 03051786 | | ADD: 2415 CURLEY CUT | | CONT: SIERRA | | TEL: (561)616-9686 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1) THE DESIGNER OF RECORD TO PROVIDE THE | | CORRECTED WIND PRESSURES (FOR "B" ZONE) | | BEFORE WINDOW & DOOR BUCK INSPECTION. | | | | 2) CORRECT A/C SQ FT AREA FOR ENERGY | | EFFICIENCY CODE ( SAME AS PLANS) | | | | 3) STORM SHUTTERS: | | A) PROVIDE KEY PLAN TO CORRELATE TO THE | | SHUTTER SCHEDULE. | | B) BOTTOM FASTENER CAULK-IN, THE VALUE | | TAKEN IS FOR CONCRETE, NOT CEMENT BLOCK! | | THIS FASTENER MAY NOT BE USED IN BLOCK, | | OR IF THIS IS USED IN FILLED CELL, THE | | CAULK-IN MUST BE IN 2500 PSI CONCRETE | | (FILLED CELL). OTHER ALTERNATIVE IS A | | DIFFERENT FASTENER FOR BLOCK. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|