2003-05-29 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03051518
 ADD: 641 34TH ST
 CONT: NEWBOLD CONST
 TEL: (561)254-0805
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1) THE R-30 INSULATION IS 12" THICK, THE
 PROPOSED ROOF TRUSSES ARE 2"X6", ADDI-
 ITIONAL INFORMATION REQUIRED FOR HOW THE
 INSULATION (R-30) WILL FIT?
  
 2) INDICATE ON EITHER THE SURVEY THE
 EXISTING CARPORT OR ON THE FLOOR PLAN
 THE DISTANCE FROM THE PROPERTY LINE?
 THE SURVEY AND THE EXISTING FLOOR PLAN
 DO NOT MATCH?
  
 3) THE PLAN INDICATES THAT THE LEDGER IS
 TO BE ANCHORED TO THE EXISTING BUILDING
 AT 2'-0" O.C., ARE THE STUDS IN THE
 EXISTING DWELLING LAID OUT AT 24"O.C.?
  
 4)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 5)1507.3.8. ASPHALT SHINGLES LOW
 SLOPE ROOFING, UNDERLAYMENT APPLICATION
 FOR ROOF SLOPES FROM 2:12 UP TO 4:12,
 UNDERLAYMENT SHAL BE A MINIMUM OF TWO
 LAYERS APPLIED AS FOLLOWS:
 1) STARTING AT THE EAVE, A 19-INCH
 STRIP OF UNDERLAYMENT SHALL BE APPLIED
 PARALLEL WITH THE EAVE AND FASTENED
 SUFFICIENTLY TO STAY IN PLACE.
 2) STARTING AT THE EAVE, 36-INCH-WIDE
 STRIPS OF UNDERLAYMENT FELT SHALL BE
 APPLIED OVER LAPPING SUCCESSIVE SHEETS
 19 INCHES AND FASTENED SUFFICIENTLY TO
 STAY IN PLACE.
  
 6) 1403.1.6 IN ORDER TO PROVIDE FOR
 INSPECTION FOR TERMITE INFESTATION,
 CLEARENCE BETWEEN EXTERIOR WALL COVERING
 AND FINAL EARTH GRADE ON THE EXTERIOR OF
 A BUILDING SHALL NOT BE LESS THAN 6".
  
 7)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 LOOK FOR COMMENTS BY THE OTHER PLAN
 REVIEW DISCIPLINES THAT MAY BE WRITTEN
 ON THE APPLICATION, PLANS, OR ATTACHED
 SEPARATELY. WHEN RESUBMITTING PLANS
 PLEASE CLEARLY INDICATE THE REVISION AND
 REMOVE AND REPLACE ANY PAGES AS NECESS-
 ARY. SUBMIT (1) SET OF OLD DRAWINGS WITH
 THE PLANS WHEN RESUBMITTING PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN
 BE FOUND, WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.