Notes
Date Text
2003-06-19 00:00:00BUILDING DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3)FL. BLD CODE 1606.1.7 THE FOLLOWING
 INFORMATION RELATED TO WIND SHALL BE
 SHOWN ON THE CONSTRUCTION DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 4) SPECIFY THE SIZE OF THE ATTIC VENTS
 ON THE WALL SECTION ON SHEET 2. SEE FBC
 2309.7.
  
 5) SPECIFY THE SIZES OF THE (2) ATTIC
 ACCESS OPENINGS ON THE FLOOR PLAN ON
 SHEET 2. SEE FBC 2309.6.
  
 6) THE 1-1/2" RECESS FOR THE BLOCK AT
 THE EXTERIOR WALL IS REQUIRED BY CITY
 AMENDMENTS TO FBC 2111.1.9. THE WALL
 SECTION ON SHEET 2 INDICATES THAT THE
 RECESS IS OPTIONAL. PLEASE CORRECT.
  
 7) SPECIFY ON THE PLANS THAT THE WALL
 BETWEEN THE GARAGE AND CONDITIONED SPACE
 IS INSULATED AS REQUIRED BY FBC CHAPTER
 13.
  
 8) THE OWNER/AGENT IS REQUIRED TO SIGN
 AND DATE THE ENERGY CALCULATION FORM.
 FBC CHAPTER 13
  
 9) FBC 1609.4 NO LONGER ALLOWS THE ONE
 THIRD STRESS INCREASE FOR STEEL
 CALCULATIONS. PLEASE REVISE THE FASTENER
 SCHEDULE ON SHEET 2 TO UPLIFT VALUES
 THAT DO NOT INCLUDE THIS INCREASE. SEE
 THE 2003 USP OR 2002 SIMPSON HIGH WIND
 RESISTANT CONSTRUCTION CATALOGS FOR
 VALUES AND NAILING REQUIREMENTS.
  
 10) PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - STRUCTURAL MULLIONS
 - OUTSWING STEEL DOORS (THE INFORMATION
 SUBMITTED IS NOT ACCEPTABLE)
 - OVERHEAD GARAGE DOOR (NEED THE SBCCI
 EVALUATION REPORT IN ADDITION TO THE
 DRAWINGS)
 - STORM PANELS (NEED THE NOA REPORT AND
 THE APPROVED DRAWINGS)
  
 11) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS.
  
 NOTE: IN ORDER TO FACILITATE PLAN REVIEW
 TIME, PLEASE RETURN OLD PLANS WITH
 RESUBMITTALS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714