Date |
Text |
2003-06-19 00:00:00 | BUILDING DENIED |
| |
| 1) IMPACT FEES MUST BE PAID TO PALM |
| BEACH COUNTY, PLANS STAMPED BY THEM AND |
| COPY OF RECEIPT SUBMITTED TO CITY OF |
| WEST PALM BEACH BUILDING DEPARTMENT, |
| BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| |
| 2) A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| PERMIT CAN BE ISSUED. |
| |
| 3)FL. BLD CODE 1606.1.7 THE FOLLOWING |
| INFORMATION RELATED TO WIND SHALL BE |
| SHOWN ON THE CONSTRUCTION DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| |
| 4) SPECIFY THE SIZE OF THE ATTIC VENTS |
| ON THE WALL SECTION ON SHEET 2. SEE FBC |
| 2309.7. |
| |
| 5) SPECIFY THE SIZES OF THE (2) ATTIC |
| ACCESS OPENINGS ON THE FLOOR PLAN ON |
| SHEET 2. SEE FBC 2309.6. |
| |
| 6) THE 1-1/2" RECESS FOR THE BLOCK AT |
| THE EXTERIOR WALL IS REQUIRED BY CITY |
| AMENDMENTS TO FBC 2111.1.9. THE WALL |
| SECTION ON SHEET 2 INDICATES THAT THE |
| RECESS IS OPTIONAL. PLEASE CORRECT. |
| |
| 7) SPECIFY ON THE PLANS THAT THE WALL |
| BETWEEN THE GARAGE AND CONDITIONED SPACE |
| IS INSULATED AS REQUIRED BY FBC CHAPTER |
| 13. |
| |
| 8) THE OWNER/AGENT IS REQUIRED TO SIGN |
| AND DATE THE ENERGY CALCULATION FORM. |
| FBC CHAPTER 13 |
| |
| 9) FBC 1609.4 NO LONGER ALLOWS THE ONE |
| THIRD STRESS INCREASE FOR STEEL |
| CALCULATIONS. PLEASE REVISE THE FASTENER |
| SCHEDULE ON SHEET 2 TO UPLIFT VALUES |
| THAT DO NOT INCLUDE THIS INCREASE. SEE |
| THE 2003 USP OR 2002 SIMPSON HIGH WIND |
| RESISTANT CONSTRUCTION CATALOGS FOR |
| VALUES AND NAILING REQUIREMENTS. |
| |
| 10) PROVIDE (2) CURRENT AND COMPLETE |
| COPIES OF SBCCI OR METRO-DADE PRODUCT |
| APPROVALS FOR: |
| - STRUCTURAL MULLIONS |
| - OUTSWING STEEL DOORS (THE INFORMATION |
| SUBMITTED IS NOT ACCEPTABLE) |
| - OVERHEAD GARAGE DOOR (NEED THE SBCCI |
| EVALUATION REPORT IN ADDITION TO THE |
| DRAWINGS) |
| - STORM PANELS (NEED THE NOA REPORT AND |
| THE APPROVED DRAWINGS) |
| |
| 11) PROVIDE (2) PRODUCT APPROVALS, KEY |
| PLANS AND INSTALLATION SCHEDULES |
| INDICATING THE SPECIFIC TYPES OF ANCHORS |
| TO BE USED FOR STORM PANELS. |
| |
| NOTE: IN ORDER TO FACILITATE PLAN REVIEW |
| TIME, PLEASE RETURN OLD PLANS WITH |
| RESUBMITTALS. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |