Date Text
2003-06-06 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 11
  
 1) SHT A-2.01 TOILET ROOM IN SALES OFF-
 ICE SHALL COMPLY WITH SECTION 11-4.22
 AND ALL SUBSECTIONS. PLEASE SUBMIT A
 DETAIL. 11-4.1.3(11)
 2) SHT A-2.01 KIT SINK SHALL COMPLY
 WITH SECTION 11-4.24 AND ALL SUBSECIONS.
 PLEASE SUBMIT A DETAIL. SINK SHALL BE
 CENTERED ON THE 48" OF THE 30X48 CLEAR
 FLOOR SPACE FOR PARRALEL APPROACH.
 3) SHT A-2.01 A DRINKING FOUNTAIN IS RE-
 QUIRED PER TABLE 403.1. ALSO SEE SECTION
 410.1.
 4) SHT P-101 SANT. RISER DIAGRAM, KIT.
 SINK SHALL NOT DRAIN INTO THE WET VENT
 OF THE BATHROOM FIXTURES. SECTION 909.1
 SINK SHALL TIE IN DOWNSTREAM OF THE BATH
 ROOM FIXTURES.
 5) SHT P-101 WATER RISER DIAGRAM, AIR
 CHAMBERS ARE NOT APPROVED. PLEASE DE-
 LEATE FROM RISER. SECTION 604.9
 6) SHT A-2.01 IS MISLABLED AS STORAGE
 BLDG FLOOR PLAN/ELEVATIONS/REFLECTED
 CEILING PLANS ECT.
  