Plan Review Notes
Plan Review Notes For Permit 03042304
Permit Number 03042304
Review Stop B
Sequence Number 1
Notes
Date Text
2003-06-03 00:00:00BULDING REVIEW CHECKLIST:
 1-REVISE ENERGY CALCULATIONS: A)A/C AREA
 DON'T MATCH ARCHITECT'S DRAWINGS.
 B)INSULATION SPECIFIED ON EXTERIOR CONC.
 BLOCK WALL DOESN'T MATCH ARCHITECT'S
 PLANS. REVISE EITHER ONE AS REQUIRED.
 C)COMPLETE ALL INFORMATION ON TOP OF
 FORM. EG: OWNER, ETC.
 D)PROVIDE ORIGINAL SIGNATURES ON BOTTOM
 OF FORM. SEC. 103.0 CHAPTER 13 FBC/01.
  
 2-SOIL TEST REPORT PROVIDED IS FOR LOT
 21. THIS IS LOT 4. REVISE AS REQ'D.
 3-IF EGRESS FROM BEDROOM IS THRU ZERO
 LOT WALL, THEN NEED RECORDED PLAT
 SHOWING EASEMENT TO ALLOW FOR EGRESS
 THRU NEIGHBOR'S PROPERTY AS REQUIRED
 BY THE BUILDING OFFICIAL.
 4-PROVIDE SPECS FOR WWM SUPPORTS IN CONC
 SLAB. SEE SEC. 1909.3 FBC 2001.
 5-GLASS BLOCK BY TUB AREA TO BE SAFETY
 GLASS IF FACE THICKNESS IS LESS THAN
 0.25". SEE SEC. 2405.2 FBC 2001.
 6-ENERGY CALCULATIONS TAKE THE CEILING
 FAN CREDIT, THEN, SPECIFY SIZE AND #
 OF CEILING FANS IN ALL ROOMS AS REQ'D
 BY TABLE 6-6 CHAPTER 13 FBC 2001.
 **NOTE: WHEN TAKING THIS CREDIT, CEILING
 FANS SHALL BE INSTALLED. THEY ARE NOT
 OPTIONAL AS CALLED FOR DEN ROOM.
 7-STORM PANELS EXCEED THE MAXIMUM PANEL
 SPAN ALLOWED BY TABLE 1 OF ENGINEERED
 DRAWINGS ACCORDING TO THE DESIGN
 PRESSURES CALCULATED BY THE ENGINEER
 OF RECORD. REVISE INSTALLATION SCHED.
 AS REQUIRED. SEC. 104.2.1.2 CITY
 AMENDMENTS TO FBC 2001.
 8-PROVIDE 2X STRUCTURAL BUCK DETAIL FOR
 ENTRY DOORS AS REQUIRED BY THE PRODUCT
 APPROVAL SUBMITTED.
 9-OWES $38.46 FOR UPDATED VALUATION AND
 RADON FEES.
 10-UPDATE THE TRUSS ANCHOR SCHEDULE AND
 ALL DETAILS THAT ARE AFFECTED BY SEC.
 1609.4.3 FBC 2001, WHICH DOES NOT
 ALLOW THE 33% INCREASE IN THE ALLOWA-
 BLE STRESS OF THE STEEL.